![Bertazzoni KTV30XV Installation Instructions; Use And Care Information Download Page 12](http://html1.mh-extra.com/html/bertazzoni/ktv30xv/ktv30xv_installation-instructions-use-and-care-information_2739222012.webp)
12
Cleaning metal grease filters
The metal grease filters can be cleaned in hot
detergent solution or washed in the dishwasher.
They should be cleaned every 2 months use, or
more frequently if use is particularly heavy.
• Open the visor by pulling it.
•
Remove the filter, pushing the lever towards the
back of the unit and at the same time pulling
downward.
•
Wash the filter without bending it, leave it to dry
thoroughly before replacing (if the surface of
the filter changes color over time, this will have
absolutely no effect on its efficiency).
• Replace, taking care to ensure that the handle
faces forward.
•
Cleaning in dishwasher may dull the finish of
the metal grease filter.
• Close the visor.
Replacing Activated Charcoal Filter
The Activated Charcoal Filters are not washable
and cannot be regenerated, and must be replaced
approximately every 4 months of operation, or
more frequently with heavy usage.
• Open the visor by pulling it.
• Remove the Filter, pushing it towards the back of
the unit and at the same time pulling downward.
• Remove the saturated Activated Charcoal Filters,
as indicated
(A)
.
• Fit the new Filters, as indicated
(B)
.
• Replace, taking care to ensure that the handle
faces forwards.
• Close the visor.
Lighting unit
• Turn off electrical supply before replacing bulbs,
and make sure bulbs are cool to touch before
proceeding.
• Remove the lamp at the base and turn slightly
to the left and the pull out from the connector
and turn slightly to the left.
• Replace the lamp with a new one of the same
type, making sure that you insert the two pins
properly into the housings on the lamp holder.
• Once the bulb pins are in place turn slightly to
the right to secure.
EN
77
INSTALLATION
Fitting the Hood canopy
BEFORE FITTING THE HOOD TO THE WALL UNIT, PROCEED AS FOLLOWS:
• Disconnect the wires to the Commands at the connectors.
• Disconnect the wires to the Light at the con-
nectors.
• The Hood can be installed directly on the
underside of the wall unit (Minimum 650 mm
from the Cooker Hob).
• Create an opening in the bottom of the wall unit,
as shown.
• Insert the hood until the side supports snap into
place.
• Fasten using the 10 screws
12a
provided.
• Lock in position by tightening the screws
Vf
from
underneath the hood.
• Open the suction panel by turning the specific knob.
• Disconnect the panel from the hood canopy by sliding the
fixing pin lever.
• Remove grease filters.
• Screw the Frame into place
using the 6 screws
12f
, re-
connect the wires to the
Commands and Light, re-
place the metal grease filter
and the Panel.
260
13
495 - 675
Gu10 self-ballasted led
lamps – listed in ac-
cordance with
ul 1993/nmx-
j-578/1-ance/
csa c22.2 No.
1993
Summary of Contents for KTV30XV