background image

 

8

REPLACEMENT PARTS 

Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available 
from factory authorized parts distributors.

 

 

CONVERSIONE TO DIFFERENT TYPES OF GAS 

Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig.  

Adaptation of the pressure regulator for use with different type of gas 

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a 
nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre-arranged from the 
factory to operate with one of these gas/pressure as indicated in the pre-arranging labels affixed on the appliance, 
package and Instruction booklet. 

To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough perform the 
following operations: 

1) Unscrew by hand the upper metal stopper of the regulator. 

2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw it again 
in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with relative indicating arrows 
on the white piece). 

3) Screw again by hand the metal stopper in the original position on the regulator.  

Operating in this way the gas regulator is converted for use with the other gas/pressure.

  

 
It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage 

  

 

 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 

To change the nozzles of the burners  use the following procedure: 

 

Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with 
those designed for the new gas supply according to the information given in TABLE  shown below. 

 

 

 
 
 

Summary of Contents for CB36500X

Page 1: ...al codes Electrical installation must be in accordance with the current CSA C22 1 Canadian Electrical Codes Part 1 and or local codes Installation of any gas fired equipment should be made by a licensed plumber A manual gas shut off valve must be installed in the gas supply line ahead of the oven in the gas flow for safety and ease of service In Massachusetts All gas products must be installed by ...

Page 2: ...he gas supply piping system any pressure testing of that system at test pressure in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa For use with a pressure regulator The regulator supplied must be used ...

Page 3: ...In order to increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance For installation instructions follow the instructions indicated in the following figures ...

Page 4: ...earance to combustible vertical surfaces above 36 91 4 cm I the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop 4 4 Wall cabinets above the rangetop must be a minimum of 36 91 4 cm for the open top burner models and a minimum of 42 106 7 cm for the sealed burner models above the rangetop co...

Page 5: ...t be grounded and properly polarized The unit is equipped witth a SJT power cord and in case of replacement the cable shall be replaced with one of the same type size and length WARNING Electrical Grounding Instructions This appliance is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket Do not cut or remove the ...

Page 6: ...ing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing For freestanding gas range model CB36500X C3W0 U7X 2 or 5 A CAUTION label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...

Page 7: ...uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa 3 Flexible Connections a If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a heavy duty AGA design certified commerciai flexible connector of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI ...

Page 8: ... regulator for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by hand the upper metal stopper of the regulator 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative...

Page 9: ...73 LP Propane 11 6300 1845 1500 439 0 36 Rapid Front L 1 55 NG 4 10400 2046 2500 732 Regulated 0 98 LP Propane 11 11400 3339 2500 732 0 47 Centre Inner 0 80 NG 4 2730 799 900 264 Regulated Dual Burner 0 50 LP Propane 11 2900 849 900 264 0 29 Centre Outer N 2 x 1 30 NG 4 15000 4394 4500 1319 Regulated N 2 x 0 83 LP Propane 11 16400 4804 4500 1319 0 65 CAUTION save the orifices removed from the appl...

Page 10: ...SCRIPTIVE CAPTION FOR HOB DESCRIPTION OF HOBS 1 Small Burner Model CB36500X CB36M500X C3W0 U or A 7X 2 or 5 A Fig A 2 Medium burner Model CB36600X CB36M600X C3Y0 U or A 7X 2 or 5 A Fig B 3 Rapid burner 4 Dual burner Fig A Fig B CONTROL PANEL DESCRIPTION On the control panel small symbols show the function of each knob or key Here as follows are the several controls that a cooker can have the symbo...

Page 11: ...e other one Tips for using burners correctly WARNING During use of each gas burner s adjust the burner flame size properly so it does not extend beyond the edge of the cooking utensil This is an instruction based on safety considerations Use suitable pots for each burner see Fig and Table When the liquid is boiling turn down the knob to the MINIMUM position Always use pots with a cover Correct fla...

Page 12: ...be cleaned frequently with soapy water Never use abrasive powder Do not leave acidi or alkaline substances on the enamelled parts such as vinegar lemon juice salt tomato sauce etc and do not wash the enamelled parts while they are still hot Cleaning the stainless steel parts Clean the parts with soapy water and dry them with a soft cloth The shine is maintained by periodically using specific stain...

Page 13: ...uct used in any commercial application 2 Repair service provided by other than a Bertazzoni authorized service agency 3 Damage or repair service to correct service provided by an unauthorized agency or the use of unauthorized parts 4 Installation not in accordance with local electrical codes or plumbing codes 5 Defects or damage due to improper storage of the product 6 Defects or damage or missing...

Page 14: ...save service Refer to warranty certificate for warranty condiftions Dealer Importer Name address phone MANUFACTURER BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tel 0522 226411 telefax 0522 226440 http www bertazzoni com SERVICE CENTERS Name Phone ...