TRIP UNIT
See Section 2.7 for hook-up information. Provides the user with a means of remote turn
ON/OFF. This input requires a contact closure to ground to turn off the high voltage. An NPN
open collector transistor logic can also be employed. When no connection is made to this
input the high voltage is enabled.
2.7
INPUT/CONTROL/MONITOR CONNECTIONS
INPUT POWER CONNECTIONS
INPUT POWER CONNECTIONS
SERIES 602C/603C/612C ONLY
SERIES 605C/606C ONLY
CONTROL AND
PIN LAYOUT
MONITORING CONNECTIONS
INPUT/CONTROL/MONITOR
ALL MODELS
CONNECTOR (P2)
Note:
To obtain local control using the internal potentiometer accessible at the top of the unit, jumper
P2 pin 4 to pin 9.
For remote potentiometer control connect the remote potentiometer as follows:
CW terminal to P2 pin 5
CCW terminal to P2 pin 3
Wiper terminal to P2 pin 4
For remote 0 to +5V voltage programming apply the input program voltage to P2 pin 4.
For remote TRIP connect P2 pin 8 to P2 pin 3