2
SECTION I – INTRODUCTION/SPECIFICATIONS
1.0
SCOPE OF MANUAL
This manual is provided to assist the user in the installation and operation of the Bertan
Series 602C, 603C, 605C, 606C and 612C modular high voltage power supplies. Statements
will apply to models in all of the Series unless reference is made to specific models. For the
protection of personnel and equipment, it is essential that this manual be thoroughly read
prior to the installation and application of power.
1.1
PURPOSE OF EQUIPMENT
The Series 602C, 603C, 605C, 606C and 612C are families of regulated fixed output polarity
modular high voltage power supplies. They provide exceptional performance in applications
such as CRT’s spectrometers, detectors, medical imaging, image intensifiers, E-Beam, I-
Beam, medical imaging and capillary electrophoresis (HPCE) systems.
1.2
DESCRIPTION
The units are fully enclosed and designed to easily satisfy system or bench top operation. A
wide range of stable output voltages, up to 30kV are available. The output voltage is
controlled locally by a minimum 15-turn potentiometer. Remote analog voltage of resistance
programming is also available to the user as a standard feature. All units offer a 0 to +5Vdc
analog monitor output proportional to the output current.
The Series 602C, 603C and 612C require an input of 115/230Vac (switch selectable) +10%,
50-60Hz. The Series 605C and 606C require a +28Vdc +10% input (or +24Vdc
±
10% for
units equipped with +24V Option). Each unit in the Series converts the applied power to a
high voltage DC output. This output voltage is highly regulated and filtered. The high voltage
assembly is fully encapsulated in silicone rubber for reliable, arc-free, stable operation.
1.3
ELECTRICAL SPECIFICATIONS
The following chart lists the output High Voltage, peak-to-peak ripple and output current for all
models in the Series 602C, 603C, 605C and 606C. The complete Model part number
consists of the Series designation followed by the Model Suffix including either a
P
or an
N
to
designate the output voltage polarity.
OUTPUT
RIPPLE
SUFFIX VOLTAGE PK to PK
602C
603C
605C
606C
-10P, N
0 to 1KV
15 mV
15mA
30mA
9mA
30mA
-15P, N 0 to 1.5KV
15 mV
10mA
20mA
6mA
20mA
-30P, N
0 to 3KV
30mV
5mA
10mA
3mA
10mA
-50P, N
0 to 5KV
50mV
2mA
5mA
1.5mA
5mA
-100P, N 0 to 10KV
200mV
1mA
2mA
750µA
2mA
-150P, N 0 to 15KV
450mV
.6mA
1.5mA
400µA
1.5mA
-200P, N 0 to 20KV
800mV
.4mA
1mA
N.A.
1mA
SERIES
MAXIMUM OUTPUT CURRENT