background image

Shanghai

 

Berry

 

Electronic

 

Tech

 

CO.,

 

Ltd

 

emergency

 

room

 

and

 

so

 

on.

 

Also

 

is

 

suitable

 

in

 

oxygen

 

bar,

 

community

 

health

 

care,

 

family,

 

sports

 

&

 

health

 

care

 

(machine

 

must

 

be

 

used

 

before

 

or

 

after

 

the

 

sport,

 

not

 

suggest

 

to

 

use

 

when

 

exercising)

 

and

 

outdoor

 

activity.

 

   

7.

 

Daily

 

maintains

 

and

 

calibration

 

is

 

unnecessary.

 

   

8.

 

Communication

 

can

 

realize

 

between

 

Bluetooth

 

and

 

upper

 

computer.

 

   

9.

 

Charge

 

is

 

available.

 

 

II.

 

Specification

 

   

1.

 

Display

 

mode:

 

OLED

 

Screen

 

   

2.

 

Spo2

 

measure

 

range:

 

35

100%

   

Spo2

 

Resolution

1%

 

Spo2

 

Accuracy:

 

in,

 

±2%

80%

100%

;

   

±3%

70%

79%

 

   

3.

 

Pulse

 

measure

 

range:

 

25

250

 

BPM

 

Pluse

 

Rate

 

Resolution

1bpm

 

Accuracy:

 

±2bpm

   

or

 

±2%

 

 

Summary of Contents for BM2000

Page 1: ...teries convenient to carry 3 Lower consumption original two 3 7V lithium batteries can continuously work for 24 hours 4 Low voltage alarm shows in screen when there s low battery may influence the normal working 5 The machine will automatically power off when there s no signal generated 6 Widely used in clinical cure such as in physicians and surgical operation department anesthesia department ped...

Page 2: ...t suggest to use when exercising and outdoor activity 7 Daily maintains and calibration is unnecessary 8 Communication can realize between Bluetooth and upper computer 9 Charge is available II Specification 1 Display mode OLED Screen 2 Spo2 measure range 35 100 Spo2 Resolution 1 Spo2 Accuracy in 2 80 100 3 70 79 3 Pulse measure range 25 250 BPM Pluse Rate Resolution 1bpm Accuracy 2bpm or 2 ...

Page 3: ...ing 80 Storage 93 IV Using Berry BSA09001P will have better performance and more comfortable experience V Operating Instructions 1 Power on and power off Power on Press POWER button machine starts up and enter main menu Power off Press POWER button for 3 seconds machine power off or the sensor dropped for 10 seconds the machine automatically power off ...

Page 4: ...when screen needs to be on press Power button 3 Communication a Open pc Bluetooth search the device the pulse oximeter s user name is BerryMed pairing mode is 0000 b Check the Bluetooth serial no when connected such as com13 c Open pc software d Choose Bluetooth serial no e Click to open f Enter display interface Power ...

Page 5: ...or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this eq...

Reviews: