Yuno tables will require a small amount of field assembly. The Yuno tables will involve installation of the leg assembly, power infeed wire 
management clip, and the ganging brackets. 

Read the following instructions for installation of the Yuno leg assembly and power infeed wire management clip. The following 
installation instructions show a yuno table with power. For assembly of yuno tables without power follow steps one and two, 
excluding the power infeed wire management clip installation.  

Begin by carefully removing all components from the box, placing the table top face down on a clean, protected surface.
Yuno table tops will come pre-assembled with crossmember attachment bar, power modules (wiring pre-assembled) and 
felt shroud.

Yuno tables will come with the following mechanical fasteners that are 
required for leg and power infeed wire clip installation:

A torx T30 bit will be required for 
installation

.

After securing the legs to both the table top and crossmember assembly, a customer 
assembling a powered yuno table will attach the power infeed wire management clips 
using screw (C). The illustrations below are for a right hand power infeed table, for a 
left hand power infeed mirror the illustration. 

Right hand facing starter table

Right hand facing add-on table

Yuno leg assemblies are unique in that they can be placed on either 
end of the table top.

Attach each leg assembly to the 
crossmember using screw (B) and to 
the table top using screw (A). 

Leg Installation Instructions

leg installation instructions

yuno installation instructions

1

2

3

(A)  

(A)  

(x12)  

(B)  

(B)  

(x4)  

(C)  

(D)  

(C)  

(x2)  

(x2)  

Summary of Contents for yuno

Page 1: ...yuno electrical installation instructions january 2017...

Page 2: ...odules wiring pre assembled and felt shroud Yuno tables will come with the following mechanical fasteners that are required for leg and power infeed wire clip installation A torx T30 bit will be requi...

Page 3: ...ose tables CONSERVEZ CES INSTRUCTIONS MISE EN GARDE Risque de blessure de choc lectrique ou de feu Puissance nominale de 120 Volts 12 Amps 1 440 Watts 60 Hz Utilisation uniquement reli la terre Cordon...

Page 4: ...he module is available as 1 receptacle and 1 dual port USB or 2 receptacles shown below This unit is a great option because it leaves the worksurface free of any distraction and allows for the full us...

Page 5: ...ount power modules are provided with a grounded SJT power cord These products are for use only with a nominal 120 volt circuit and has a grounded plug as illustrated below Make sure that these power m...

Page 6: ...d on tables Specify a right or left power infeed for the starter and add on table configurations When starting to connect your power you first need to identify your starter table SKU pictured above is...

Page 7: ...es Control module with 10 grounded plug Allows users to connect up to 8 modules off of one feed 8 55 tables and 4 63 tables A plug designed to be inserted into a receptacle in one position only When s...

Page 8: ...n Storing Yuno Tables Move the first table near the connecting table 1 With two people lift the table above the table on the bottom aligning the legs 2 Slowly lower the table down and repeat Tables wi...

Reviews: