Automatic water tap with water level control (WZN) – optional
The basin replenishes automatically. The basin will be filled up to the operational level. This
level will be automatically controlled through a water level electrode. Please ensure
cleanliness of the electrode at all times. If the water level falls below the operational level,
the tap will replenish automatically up to the previous level.
This function doesn’t avoid replacement of water.
Please replace the water regularly!
Dry run protection
If the pasta cooker is switched on and there is no water in the basin, it heats up to over 180°C
(heating) and is then switched off immediately by the over temperature switch. Only from below
90°C, the heater turns on again. Caution is advised and it is forbidden to accelerate the cooling
process abruptly. Filling with cold water can cause stress cracks in the cooker. If the electronics
fail when switching off (technical defect), a mechanical safety temperature limiter (STB) is
additionally installed on the heater, which switches off at 237°C at the latest. Only after the pool
has cooled can it be reset again by pressing in the unlocking button. The number of "emergency
shutdowns" and thus the lifetime of the STB is limited.
After filling with fresh water, the pasta cooker can be switched on again.
End of service / intervals
At the end of the service or during service intervals, turn the thermostat in OFF position.
Decommissioning
If the unit will not be used for a longer period, please pull the plug form the socket. Make
sure that no liquids can penetrate into the unit and never clean it with a pressure cleaner.