English |
11
1 609 92A 16U • 27.3.15
Battery Charge-control Indication
The three green LEDs of the battery charge-control
indicator
3
show the charging status of the battery
5
. The battery charge-control indicator only illumi-
nates for 3 seconds after start-up.
When no LED lights up after switching on, then the
battery is defective and must be replaced.
Battery Insertion/Removal (see figures A1 – A2)
Do not use force to insert the battery.
The bat-
tery is designed in such a way that it can only be
inserted into the vacuum cleaner when it is in the
right position.
– Slide the battery
5
all the way into the battery
compartment
11
.
– To remove the battery pack
5
, press the unlock-
ing buttons
12
and pull the battery pack out of
the battery port
11
.
Mounting the Crevice Nozzle
(see figure B)
Remove the battery before cleaning or per-
forming maintenance on the vacuum cleaner,
making tool adjustments, changing accesso-
ries or storing the vacuum cleaner.
This safety
measure prevents the vacuum cleaner from be-
ing started accidentally.
The crevice nozzle
9
can be connected directly to
the dust chamber
8
.
– Firmly insert the crevice nozzle
9
into the intake
port
10
on the dust chamber
8
with the mark
shown in the illustration facing down.
Operation
Remove the battery before cleaning or per-
forming maintenance on the vacuum cleaner,
making tool adjustments, changing accesso-
ries or storing the vacuum cleaner.
This safety
measure prevents the vacuum cleaner from be-
ing started accidentally.
Starting Operation
Before vacuuming, ensure that the filter as-
sembly is assembled securely.
Only use an undamaged filter (no cracks, small
holes, etc.). Replace a damaged filter immedi-
ately.
Switching On and Off
To save energy, only switch the vacuum cleaner on
when using it.
– To
switch on
the vacuum cleaner, press the
On/Off button
2
.
– To
switch off
the vacuum cleaner, press the
On/Off button
2
again.
Maintenance and Service
Maintenance and Cleaning
In all correspondence and spare parts orders,
please always include the 6-digit article number
given on the type plate of the vacuum cleaner.
Remove the battery before cleaning or per-
forming maintenance on the vacuum cleaner,
making tool adjustments, changing accesso-
ries or storing the vacuum cleaner.
This safety
measure prevents the vacuum cleaner from be-
ing started accidentally.
For safe and proper working, always keep the
vacuum cleaner and ventilation slots clean.
– Clean the vacuum cleaner housing from time to
time using a moist cloth.
– Clean soiled charger contacts using a dry cloth.
Cleaning the Dust Cup (see figures C1–C3)
To maintain the optimum performance of the vacu-
um cleaner, clean the dust cup
8
after each use.
– Hold the vacuum cleaner down slightly so that
dust cannot fall out of the dust chamber when
the vacuum cleaner is opened.
– Press release button
1
and remove the dust cup
8
from the motor housing
7
.
– Reach into the recess
13
on the motor housing
7
and pull the filter unit
15
off the motor housing
by the filter seal
14
.
– Shake/tap out the dust cup
8
over a suitable
waste bin.
– If required, clean the dust cup with a moist cloth.
If required, clean the filter assembly (see “Clean-
ing the Filter Assembly”, page 12).
– Insert the filter unit
15
with the filter seal
14
back
into the motor housing
7
.
Afterwards, hang the dust cup at the bottom into
the motor housing, apply light pressure until the
dust cup can be heard to engage.
LED
Capacity
Continuous lighting 3 x green
≥
2/3
Continuous lighting 2 x green
≥
1/3
Continuous lighting 1 x green
<1/3
Flashing light 1 x green
Reserve