26
TECHNICAL DATA
Nominal voltage
180 V
– 264 V 47-63 Hz
Current consumption
5,2 A (by maximum charging current)
Charging voltage
14-15 V (± 0,3%) adjustable
Float Charging Voltage
min. 13.3 V (± 0,3%)
Service Mode Voltage
13,9 V (
0,3%) adjustable
Reactivation Voltage
max.15,5 V (
0,3%)
Max. charging current
70 A (12 V) 35A (24V) 10A (6V) ± 3%
Minimum battery voltage
3 V
Operational temperature
-20°C
– 50°C
Cooling
Fan controlled by temperature
Charging characteristic
IUoU
Battery types
Lead-Acid, Lead-GEL, AGM
Battery capacity
25-700 Ah
Weight (without charging power)
3,6
On charge or service operation the battery must have at least 3V to enable the
charger to start.
The quality of output voltage and current of a charger is very important. Undesired
variations and ripples lead to warming up and to wear the positive terminal.
The
Berner Trading Holding GmbH
battery charger are characterised by a very
clean tension and current.
CONTENT
TELLERERKL
• HIGH FREQUENCY CHARGER BHFL75 portable.
• Main cable (2m) Schuko-Connector with protective contacts plugs
• Battery cable (3m) red/black with full isolation with metal terminal clamps.
•
This operating manual.
MAINTENANCE
The charger must be protected from strong pollution, liquid and moisture.
Cause this may damage the internal electronics.
The charger is maintenance free. If the cables or parts are damaged they must be
replaced. The housing can only be cleaned with dry cloth. Don’t use any liquid, or
conductive materials. Before cleaning disconnect the AC Supply and battery cables.