![Berner 215208 Manual Download Page 13](http://html.mh-extra.com/html/berner/215208/215208_manual_2738350013.webp)
12
DC voltage testing:
When the probe tips are connected to a DC voltage that lies within the rated voltage range, one of
the lower (6 V + -) or bottom LED indicators lights up to indicate the corresponding voltage. The
upper LED indicators show the voltage, whereby the reference pole is connected to the large
hand element.
AC voltage testing:
When the probe tips are connected to an AC voltage that lies within the rated voltage range, both
of the upper (6 V + -) and the lower LED indicators light up to indicate the corresponding voltage.
Simultaneous lighting up of the upper LEDs indicates the presence of an AC voltage.
Phase search:
Hold one test tip against the earth (ground) lead and use the other tip to check the remaining
leads. The Berner AC/DC Easy indicates the AC voltage for the phase in question. FI/RCD is not
triggered.
Technical data
Voltage range
6 – 400 V AC/DC
Overvoltage category
CAT III 400 V
Testing standard
IEC/EN 61243-3:2011-02
Frequency range
0...500 Hz
Duty
max. 30 s on \ 240 s off
Degree of protection
IP 65
Operating temperature
-15 °C to 45 °C