Control  line  adopts  twisted  pair  cable  which  is  better  than  parallel  line  in  transmission 

distance. 

2

) 

Decoder  adopts  dual-core  STP  (shielded  twisted  pair)  with  RS485  communication.  Cable 

length should be within 1200m. Decoder can adopt chain connection or star connection. RS

+(

A

,RS

-(

B

is signal end, connecting to A and B port of RS485 host (reverse connection 

forbidden). 

3

) 

Multi decoders connection should be finished between the two farthest decoders, moreover 

adding 120Ω resistor. 

12.   RS485 controlled device use method: 

 

Wiring  method:  matrix  switcher  directly  connects  to  decoder.  PC  can  adopt  active  or  passive 

RS232-485 converter for connecting with decoder. 

 

When distance over 1200m or interference excesses, it is necessary to install a RS485 repeater. 

 

When adopting star 

wiring, we’d better use RS485HUB which can turn 1 channel RS485 into 4 

channels RS485. Thus all channels realize better isolation and less interference between each 

other, besides effective transmission distance can also be lengthened. 

 

When interference too serious or adopting non-twisted pair which leads to hard or disable control, 

we should adopt RS485HUB or RS485 repeater suchlike devices. 

13.   Wiring Diagram: 

 

RS+ (A) refers to RS485 plus communication; RS-(B) refers to RS485 minus communication.   

 

DC12V and AC24V refer to the wiring terminal of power supply for camera.   

 

AUX1 and AUX2 refer to the control switchers of camera power supply, wiper or light. 