Bernee
®
5
/
8
10
001010
42
101010
11
001101
43
101011
12
001100
44
101100
13
001101
45
101101
14
001110
46
101110
15
001111
47
101111
16
010000
48
110000
17
010101
49
110001
18
010110
50
110010
19
010011
51
110011
20
010100
52
110100
21
010101
53
110101
22
010110
54
110110
23
010111
55
110111
24
011000
56
111000
25
011001
57
111001
26
011010
58
111010
27
011011
59
111011
28
011100
60
111100
29
011101
61
111101
30
011110
62
111110
31
011111
63
111111
(
1
)
Dialup switcher: ON=1; OFF=0.
(
2
)
Address encoding is based on binary system.
(
3
)
Some hosts addresses initiate as 0, and some initiate from 1.
10. Common Faults Analysis & Solutions
Fault Features
Analysis & Solutions
Powered light cannot shine
1. Whether supplied voltage is AC220V
2. Maybe power switcher shut or fuse burnt
Out of control
2. Whether PC system is normal and whether communication port
setting accords with hardware requirement
3. Whether address code switcher setting accords with controlled
camera address (for NO.1 camera address, some hosts show as
0; but some hosts show as 1)
4. Protocol setting incorrect
Close control available; remote
control unavailable
1. RS485 converter lacks driving force for output.
2. Wiring distance over 1200m should add RS485 repeater or
RS485 distributer.
11. Wiring Diagram: