Custom molds for the m-Speaker
For custom fi ttings two different types of molds can be attached to the M-Speaker. The Micro Mold
and the Lite Tip come with an adapter already inserted, colored red (right) or blue (left) to indicate
which ear. The color dot on the top of the custom mold indicates the front and top position in the ear
canal.
Tools for Custom Molds
To attach and detach the M-Speaker unit to and from a custom mold, two different tools are designed
to be used.
Lite Tip Tool for Lite Tip and Micro Mold
·
attaching the Lite Tip or the Micro Mold onto the M-Speaker unit
·
detaching the M-Speaker unit from a Lite Tip
Disassembly Tool for Micro Mold
The Micro Mold disassembly tool is intended for detaching the Micro Mold from the M-Speaker.
1 Front-top indicator
2 Micro Mold adapter
3 WaxStop fi lter
4 Pull-out string
5 Lite Tip adapter
6 NoWax fi lter
CN_ILLU_NRCostumMoldPspeakerDetaching_BW_HI
For mounting a curved
speaker (in any mold)
For dismounting a speaker
from a Lite Tip
Micro Mold
Lite Tip
134056_NR_Fitting_Guide_generic_US_Private_Label.indd 12
14.03.13 13:37
NaNo RITE HEaRINg SySTEmS
13
Attaching the Lite Tip and the Micro Mold to the M-Speaker Unit
CN_ILLU_NRCostumMoldPspeakerAttaching3_CMYK_HI
1 Use the cup pin of the Lite Tip tool for curved
receivers.
2 Place the receiver into the tool and push the
wire into the groove to obtain a stable
attachment. Make sure that the NoWax is on
the receiver (see page 18).
3 Before inserting the receiver into the mold,
turn the receiver so that the wire and up
marking on the mold are properly aligned.
Carefully center the receiver in the middle of
the adapter before pushing it in.
4 Insert the receiver into the custom mold.
4 a)
Micro Mold:
Align and fi rmly insert the
M-Speaker unit into the Micro Mold until
it clicks into place. This should be done
carefully.
4 b)
Lite Tip:
Place the Lite Tip against the table
and push the receiver fi rmly in place. Make
sure that the front of the receiver is fully
inserted and fl ush with the front of the
Lite Tip. This should be done carefully.
5 Make sure that the mold sits correctly in the
patient’s ear and check the position of the
wire. If necessary the wire is bendable by
heating.
LT_ILLU_LiteT
ipOnMspeakerAttaching1_CMYK_HI
LT_ILLU_LiteTipOnMspeakerAttaching2_CMYK_HI
LT_ILLU_LiteTipOnMspeakerAttaching3_CMYK_HI
LT_ILLU_LiteTipOnMspeakerAttaching4_CMYK_HI
1
2
4 b)
3
4 a)
134056_NR_Fitting_Guide_generic_US_Private_Label.indd 13
14.03.13 13:37