7.4 MUT2660
7.4.1 Dimensions and main features
The MUT2660 sensor is suitable for fixed installation in pipes from DN80 up to DN500.
The installation and assembly/disassembly of the flowmeter requires a 40mm hole drilling on the pipe and a
threaded sleeve welding.
ATTENTION: For installation, assembly, and disassembly of the meter, the pipe must be empty - the sensor does
not have Hot-Tap functionality.
The maximum pressure at which the meter can operate is 10bar.
Main features
DN Range
DN 80 - DN 500
3” - 20”
Maximum pressure
10 bar
Temperature limits (process)
-20°C ÷ +80°C
-4°F ÷ +176°F
Protection class - Separate
IP68
ATEX/IECEx (only Separate)
Ex mb IIC T6...T4 Gb
Ex mb IIIC T85°C...T135°C Db
-20°C ≤ Ta ≤ +60°C
Materials in contact with the liquid
Sensor body
AISI316
Measuring head
POM
Electrodes
AISI316L
Safety ring
AISI304
Sensor body
Ottone
O-Ring
NBR
74
3
0
Ø 33,70
285
~ 6
5
3
67
Probe/Measuring head
Safety ring
11/4” threaded nipple
GAS/BSP
Locking ring
Sensor body
Fig. 78