Performance after mains breakdown/return of mains supply

 

Mains breakdown shorter than 0.2 s: 

The function is not impaired.

 

Mains breakdown longer than 0.2 s: 

There is no function during the mains breakdown. The current configuration is saved in 

non-volatile memory.

 

Return of mains supply:  

The application module executes an initialisation for approx. 5 s, during which the lighting 

will be switched on. Motion detection starts thereafter. If no motion is detected during the 

first 5 s, the lighting is switched off. The saved configuration is loaded from memory. During 

this period local operation via the button or extension unit can be used. 

4.  Operation

Operating concept

(8)

(7)

Fig. 2: Operating and display elements

(7)  Button
(8)  Status LED 
Operation is executed by pushing the button (7) on the motion detector:

 

A short press of the button switches the operating modes. The operating mode is displayed 

via the status LED behind the optics cover of the motion detector. 

 

Keeping the button pressed activates special functions. Selection of the special functions is 

supported by the LED display (Fig. 3).

Function 

Party function

Teach-In

Keylock

Presence 

simulation

Load setting 

mode

1)

LED display

Hold time 

operation 

button

> 5 s

> 10 s

> 15 s

> 20 s 

> 25 s

1)

 

Only on universal switch insert and universal flush-mounted dimmer

Fig. 3: Selection of the special functions and LED display

Summary of Contents for 8534 51 series

Page 1: ...y result in damage to the device fire or other hazards The radio transmission is not suitable for safety or alarm applications Due to its detection behaviour the device is not suitable for use in burg...

Page 2: ...nsitivity Adjustable detection angle for adaptation of the detection area Additional adjustment of the response brightness via Teach In function Party function Presence simulation Optional extension u...

Page 3: ...oaded from memory During this period local operation via the button or extension unit can be used 4 Operation Operating concept 8 7 Fig 2 Operating and display elements 7 Button 8 Status LED Operation...

Page 4: ...ent OFF Table 1 Display of operating modes Disabling enabling operating mode selection via button Keep the button pressed for more than 15 seconds until the status LED is flashing green Fig 3 Selectio...

Page 5: ...tches the lighting on for 2 hours During this time no extension unit or ra dio commands are executed Keep the button pressed for more than 5 seconds until the status LED is flashing red Fig 3 The ligh...

Page 6: ...range The connected load blinks once The device is in selection mode If there is no further operation within the next 10 seconds the insert swiches to switching dimming operation Briefly press the but...

Page 7: ...ve the motion orientation a distinction is made between direct approach and trans verse motion Motions transverse to the motion detector can be detected better than moti ons toward the motion detector...

Page 8: ...le must be reset to factory settings If available fix dismantling protection with screw 5 After radio configuration and start up click the design cover 4 into place on the applicati on module 3 5 2 St...

Page 9: ...rformance Test mode must be used to test the detection performance In test mode the motion detector works independent of brightness Each detection switches the lighting and the status LED on for 3 sec...

Page 10: ...sed The following can be configured The local operation of the load connected to the insert Radio commands to control other receivers Functions which are executed when the radio commands are received...

Page 11: ...N for the set delay time The brightness evaluation only takes place on the ma ster the slave only detects motion Can only be configured between radio motion detec tors Delete No function Assignment to...

Page 12: ...e motion detec tor indicates the currently configured function T 150 90 45 45 90 fct cfg Select function at receiver Repeated short press on fct button on the motion detector until the desired functio...

Page 13: ...pply for radio application modules then it can only be configured as a transmitting extension unit slave see Executing a master slave configuration Down below there is an illustration of the configura...

Page 14: ...essful saving the fct LED signals the saved function A quick blinking of the cfg LED indicates a combi nation that is not possible or an error Finish configuration Short press on cfg button on the rad...

Page 15: ...d master light up in red colour T 150 90 45 45 90 fct cfg T 150 90 45 45 90 fct cfg All receivers within radio range also indicate the confi guration mode Select function at receiver Short press on cf...

Page 16: ...above on each receiver to be integrated and confirm function on the receiver Finish configuration Short press on cfg button on the transmitter Setting of switch on time for function timer In order to...

Page 17: ...nfiguration of the radio motion detector Settings of the insert switch on brightness level load setting are not reset 6 Appendix 6 1 Technical data Connection Mounting on suitable inserts Power supply...

Page 18: ...erest of technical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point of sale or ship the device postage free...

Reviews: