Radio motion detector comfort 1.1 m/2.2 m quicklink
Page 7/18
6W-5827
09-2012
5. Information for electricians
5.1 Installation and electrical connection
Selecting installation location
A minimum distance between the transmitter and corresponding receiver of about 1 m must be
maintained.
A minimum distance to electronic devices which emit high frequency signals such as computers,
electronic transformers or microwave devices of approx. 0.5 m must be maintained.
Mounting on or close to metal surfaces may cause impairment of the radio
transmission.
Take material penetration into account. The range of the system can be optimised by selecting
the best possible installation site:
Material
Degree of material penetration
Wood, plaster, plasterboard, uncoated glass
approx. 90 %
Brick, press boards
approx. 70 %
Reinforced concrete, underfloor heating
approx. 30 %
Metal, metal grids, aluminium laminates,
coated glass
approx. 10 %
Rain, snow
approx. 1 ... 40 %
Table 4: Material penetration
Observe the motion orientation: a distinction is made between direct approach and trans
-
verse motion. Motions transverse to the motion detector can be detected better than moti
-
ons toward the motion detector (Fig. 4).
Select an installation location that is free of vibration. Vibrations can cause undesired
switching.
Avoid sources of interference in the detection area. Sources of interference, e.g. heating
elements, ventilation systems, air conditioners and lamps that are cooling down can cause
undesired switching (Fig. 4).
To avoid disturbing influences, the detection angle can be restricted (see Restriction of the
detection area).
180°
ç
ç
1,10 m
2,2 m
Fig 4: Installation location of the motion detectors
Assembly of the device (Figure 1)
Information on electrical connection are to be taken from the operating instruction of for the
insert.
Attach the bottom part of the application module (3) together with frame (2) to a suitable
insert (1) and establish a connection between insert and the application module via the in
-
terface between application and power module (6).
As soon as voltage is supplied to the application module, the status LED indicates the com
-
patibility to the insert used.