background image

2/6

09/2015

Blind insert comfort

2.  Design and layout of the device

(2)

(1)

(3)

(5)

(4)

(6)

Figure 1: Shutter insert

(1)  Shutter insert
(2)  Frames
(3)  Application module bottom part e.g. from a push-button for blinds
(4)  Screw for dismantling protection (not R.1/R.3)
(5)  Blind button design cover
(6)  Connecting terminals

3.  Function

Correct use

 

Switching electrically operated blinds, shutters, awnings and similar hangings.

 

circuiting of extension units push-buttons for blinds, blind inserts, key push-buttons for 

blinds

 

Only suitable for use in indoor areas with no drip and no spray water.

 

Installation into wall box according to DIN 49073.

 

Operate with suitable application module (see Chapter 6.2, "Accessories")

Product characteristics

 

2 mechanically and electrically mutually locked relay contacts.

4.  Operation

These instructions describe the installation of the shutter insert. The operation and function of 

the application modules are described in the instructions of the respective application module.

  The operation of extension units is only possible if a cover is attached to the main unit.

Summary of Contents for 8522 11 0 Series

Page 1: ... electric shock Do not operate device without application module If several drives should be connected in parallel to one output it is mandatory to observe the manufacturer s data use a cut off relay where required Motors could be destroyed Use blind drives with mechanical or electrical final position switches only Check final position switches for correct adjustment Observe motor manufacturer s d...

Page 2: ...buttons for blinds blind inserts key push buttons for blinds Only suitable for use in indoor areas with no drip and no spray water Installation into wall box according to DIN 49073 Operate with suitable application module see Chapter 6 2 Accessories Product characteristics 2 mechanically and electrically mutually locked relay contacts 4 Operation These instructions describe the installation of the...

Page 3: ...protection Circuit shutter insert according to circuiting diagram Figure 2 Mount shutter insert in wall box recommended deep box The connecting terminals must be at the bottom Attach frame and application module see instructions for application module Control by sensors Sensors such as wind precipitation sensors are used e g to protect awnings from damage If a threshold is exceeded on the sensors ...

Page 4: ...ension unit Individual control with push button for blind extension unit according to circuiting diagram 503520 Individual control with key push button for shutter extension unit Circuit individual control with key push button for shutter extension unit according to circui ting diagram ...

Page 5: ...rt Master and group control Circuit master and group control according to circuiting diagram Master control under application of various RCCBs Circuit master control under application of various RCCBs according to circuiting diagram ...

Page 6: ...m Mounting orientation connecting terminals downwards Housing installation depth 22 mm Claw guide installation depth 32 mm 6 2 Accessories Push button for blinds order no 8524 11 xx Blind time switch order no 8574 11 xx Radio push button for shutters quicklink order no 8524 51 xx Radio shutter timer quicklink order no 8574 51 xx 6 3 Warranty We reserve the right to make technical and formal change...

Reviews: