Berkeley 10LTHH Manual Download Page 24

Pièces de rechange

24

N° de Modèle

10LTHH

15LTHH

20LTHH

25LTHH

10LTHH3

15LTHH3

20LTHH3

25LTHH3

10LTHH3-575T

15LTHH3-575T

20LTHH3-575T

25LTHH3-575T

Réf.

Désignation

Qté

1 ch

1-1/2 ch

2 ch

2-1/2 ch

1

Moteur monophasé de 115/230 V

1

J218-596PKG

J218-601PKG

J218-883APKG

J218-628A

1

Moteur, 230/460V triphasé

1

AP100EL

AP100FL

AP100GL

AP100G5L

1

Moteur 575V TEFC

1

J218-998AC

J218-999AC

J218-1000AC

J218-1001AC

2

Déflecteur d'eau

1

17351-0009

17351-0009

17351-0009

17351-0009

3

Plaque d'étanchéité

1

C3-155

C3-155

C3-117

C3-117

4

Joint de la plaque d'étanchéité

1

C20-86

C20-86

C20-87

C20-87

5

Joint d'arbre

1

U109-6A

U109-6A

U109-6A

U109-6A

6

Impulseur (monophasé)

1

C105-92PKB

C105-92PC

C105-214PDA

C105-214PA

6

Impulseur (triphasé)

1

C105-92PKBA

C105-92PCA

C105-214PDA

C105-214PA

6A

Vis de l'impulseur*

1

C30-14SS

C30-47SS

C30-14SS

C30-14SS

7

Diffuseur

1

C101-276P

C101-276P

C101-182

C101-182

7A

Vis de 10-24 po x 1 po de long

2

U30-696SS

U30-696SS

7A

Vis à métaux de 8-32 x 7/8 po de long

2

U30-53SS

U30-53SS

8

Bague du diffuseur

1

C21-10

C21-10

C21-2

C21-2

9

Corps de la pompe

1

C76-67

C76-67

C76-68

C76-68

10

Bouchon fileté à tête hexagonale 

de 1/4 de po NPT

1

U78-941ZPV

U78-941ZPV

U78-941ZPV

U78-941ZPV

11

Socle

1

C4-82

C4-82

C4-82

C4-82

12

Vis à chapeaux inférieure 

de 3/8-16 x 1 1/4 po

2

U30-75ZP

U30-75ZP

U30-75ZP†

U30-75ZP†

13

Vis à chapeaux supérieure 

de 3/8-16 x 1 po

2

U30-74ZP

U30-74ZP

U30-74ZP†

U30-74ZP†

14

Patin du moteur

1

C35-5

C35-5

C35-5

C35-5

15

Vis à chapeaux de 3/8-16 x 3/4 po

6

U30-72ZP

U30-72ZP

15

Vis à chapeaux de 5/16-18 x 3/4 po

8

U30-60ZP

U30-60ZP

Rondelle-frein de 3/8 de po

2

U43-12ZP

U43-12ZP

U43-12ZP

U43-12ZP

Écrous à six pans de 3/16-18 

2

U36-37ZP

U36-37ZP

U36-37ZP

U36-37ZP

• Pièces non illustrées.
* Dans le cas des modèles 10LTHH et 15 LTHH, ne pas utiliser les vis de l’impulseur.
† Les modèles 20LTHH et 25LTHH utilisent (4) vis à tête creuse U30-99SS (3/8-16 x 1 po).

3621 1199SPC

1

2

3

13

14

15

12

7A

11

5

6

7

8

4

9

6A

10

Summary of Contents for 10LTHH

Page 1: ...AL Self Priming Centrifugal Pump 2007 BE536 Rev 5 2 07 LTHH Series Installation Operation Parts For further operating installation or maintenance assistance Call 1 262 728 9181 293 Wright Street Delav...

Page 2: ...pressure hazard and possible injury do not use in a pressure tank domestic water system Do not use as a booster pump pressurized suction may cause pump body to explode Do not allow pump or piping syst...

Page 3: ...leg ambient compen sated extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and Berkeley s WICOR s only duty is to repair or replace defective...

Page 4: ...Add sections of pipe as needed using Teflon tape on male threads Be sure that all suction pipe is leakproof or pump will lose prime and fail to pump Install foot valve 10 to 20 feet below the lowest l...

Page 5: ...NSTALLATION NOTICE Use only Teflon tape or Teflon based joint compounds for making all threaded connections to the pump itself Do not use pipe joint com pounds on plastic pumps they can react with the...

Page 6: ...ECTOR To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Attach the power lead wires to the power lead termi nals Make sure the wire...

Page 7: ...d ly which could cause injury or property damage Disconnect power before servicing motor 9 If this procedure or the wiring diagrams are confusing consult a licensed electrician PRIMING THE PUMP NOTICE...

Page 8: ...all pressure in system and refill pump and piping with cold water Pump and piping need not be disconnected to repair or replace motor or seal see Figure 13 If motor is replaced replace the shaft seal...

Page 9: ...ber Cup on ceramic seat with liquid soap Be sparing 3 Put clean cardboard washer on seal face With thumb pressure press ceramic seal half firmly and squarely into seal cavity See Figure 18 Polished fa...

Page 10: ...diffuser on seal plate with two screws 13 Follow instructions under Pump Reassembly PUMP REASSEMBLY 1 Clean gasket surfaces on pump body and seal plate install new gasket 2 Slide motor seal plate ass...

Page 11: ...all connections on suction line 3 Leaking foot valve 3 Replace foot valve Pump has lost prime through In installation already in use 1 Air leaks 1 Check all connections on suction line and shaft seal...

Page 12: ...14SS C30 47SS C30 14SS C30 14SS 7 Diffuser 1 C101 276P C101 276P C101 182 C101 182 7A Screw 10 24 x1 Lg Hex Head 2 U30 696SS U30 696SS 7A Machine screw 8 32x7 8 Lg 2 U30 53SS U30 53SS 8 Diffuser Ring...

Page 13: ...a amor age automatique 2007 BE536 R v 2 5 07 S ries LTHH Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 262 728 91...

Page 14: ...eau domestique Ne pas utiliser cette pompe en tant que pompe de surpression le corps de la pompe risque d ex ploser si l aspiration est mise sous pression Ne pas laisser geler la pompe ni aucun autre...

Page 15: ...tre les surcharges thermiques d clenchement extra rapide trois pieds et temp rature ambiante compens e de la dimension recommand e ne sont pas utilis s notre garantie sera annul e Le seul recours de l...

Page 16: ...aspiration puis les abaisser dans le puits Ajouter d autres longueurs de tuyaux selon le besoin en enveloppant tous les filets m les de ruban t flon S assurer que tous les tuyaux d aspiration sont ta...

Page 17: ...s pression ni l utiliser en tant que pompe de surpression INSTALLATION DE LA POMPE NOTA Pour le branchement de tous les raccords filet s sur la pompe n utiliser que du ruban t flon ou de la p te d tan...

Page 18: ...teur gauche jusqu ce que 115 apparaisse dans la fen tre du cadran 3 Brancher les fils d alimentation sur les bornes S assurer que les fils sont bien retenus en place 4 Brancher le fil de mise la terre...

Page 19: ...sse de fonctionner le protecteur contre les surcharges thermiques risque de red marrer inopin ment ce qui risque de causer des blessures ou des dommages mat riels Toujours couper le courant avant d in...

Page 20: ...la pression du syst me puis refaire le plein de la pompe et des tuyaux avec de l eau froide Pour r parer le moteur ou le remplacer ainsi que les joints la pompe et les tuyaux doivent tre d branch s F...

Page 21: ...quide 3 Mettre la rondelle en carton propre sur la surface d tanch it Avec la pression des pouces pousser fermement la moiti du joint en c ramique d querre dans la cavit du joint du dissipateur voir l...

Page 22: ...tructions figurant sous Remontage de la pompe REMONTAGE DE LA POMPE 1 Nettoyer les surfaces d appui du joint sur le corps de la pompe et la plaque d tanch it poser un joint neuf 2 Glisser l ensemble m...

Page 23: ...le cas d une installation d j en service 1 cause de prises d air 1 V rifier tous les raccords du tuyau d aspiration et le joint de l arbre 2 parce que le niveau d eau est plus 2 Abaisser le tuyau d a...

Page 24: ...C101 182 C101 182 7A Vis de 10 24 po x 1 po de long 2 U30 696SS U30 696SS 7A Vis m taux de 8 32 x 7 8 po de long 2 U30 53SS U30 53SS 8 Bague du diffuseur 1 C21 10 C21 10 C21 2 C21 2 9 Corps de la pom...