Bering OptiPac-3 8631AF Upgrade Instructions Download Page 1

Page 1 of 6

8631AF-8032AF Upgrade Instructions

15-18032-81 Revision A

This document includes instructions for changing an OptiPac-3 8631AF to a 
RDPac 8032AF. 
The procedure requires new firmware upgrade, removal and replacement of the 
cover, drive plate, and one optical drive.

Contents

The following parts should be included in the upgrade kit. If any part is missing 
or damaged, contact Bering Customer Service at the above address.
1 8631AF-8032AF Upgrade Instructions (this document)
1 Removable hard drive (RHD)
1 RHD adapter
1 Firmware cartridge
1 8032AF users manual
1 Upgrade label
1 Set of keys
1 Hardware kit

Requirements

Only qualified technical personnel should perform this procedure

Required Tools:

#2 Phillips screwdriver
1/4” Hex nut driver
Static free workbench

Overview

The procedure performs the following general steps to upgrade the system.

Install new firmware using the Firmware cartridge

Remove cover 

Remove drive plate

Remove right optical drive

Install new RHD to the right side of drive plate

Install new RHD adapter

Install drive plate

Plug SCSI cable and DC harness into drives

Install cover