6 .2 .2 Master board connection
Follow the instructions reported on the previous paragraph
in order to connect the Master Board independently to the
electricity network. The Master Board needs to be connect-
ed to the related equipment (or to the equipment battery)
by means of a special Bus connection with bi-polar cable
(cable not supplied).
Use a H05-VV-F-3GI sheathed cable to make the connec-
tion. The minimum section size of the cable conductors
needs to be of 0,5 mm
2
(with adequate length). Connect
one side of the bi-polar cable to the mounting jig that is
placed on the Master board (see arrow, Figure 11) and
connect the other side of the cable inside the boards panel
that is placed inside the equipment.
The Figure 12 shows the left jig placed next to the equip-
ment switch on button (The connection can me made also
to the right jig; see Figure 13). Use the same jigs shown on
Figure 12 and Figure 13 in case you need to connect more
than one equipment (see paragraph 6.4.2).
Figure 11
Figure 12
Figure 13
As largely detailed on the following paragraphs, inside the
Master board you will find the auxiliary devices jigs ( e.g.
pumps, probes, mixing-valve, etc…).
Remove the DIN guide (placed inside the Master Board) to
access the mounting jig.
Unscrew the two screws on the DIN guide as indicated on
Figure 14. Once unscrewed the two screws, remove the
Din bar to fully access the jig inside the Master Board (see
Figure 14
Figure 15