Fault A09
Position the function selector to (OFF), wait 5-6 seconds then set it
to the required position (summer mode) or
(winter mode). If
the reset attempts do not reactivate the boiler, request the intervention
of the Technical Assistance Service.
Fault A09
The boiler is equipped with an auto-diagnostic system which, based
on the total number of hours in certain operating conditions, can signal
the need to clean the primary exchanger (alarm code 09 and flue gas
meter >2,500).
Once the cleaning operation has been completed, using the special kit
supplied as an accessory, the total hour meter will need to be reset to
zero as follows:
- switch off the power supply
- remove the shell
- turning the instrument panel towards you
- unscrew the two screws of the small cover on the electronic board to
have access to the terminals
BOILER STATUS
DISPLAY
TYPES OF ALARMS
Off status (OFF)
OFF
None
Stand-by
-
Signal
ACF alarm lockout module
A01
Definitive lockout
ACF electronics fault alarm
25 C.S.I. - 30 C.S.I./R.S.I.:
fumes exhaust - air intake obstruction alarm
Limit thermostat alarm
A02
Definitive lockout
Tacho fan alarm
A03
Definitive lockout
20 R.S.I.:
air pressure switch alarm
Water pressure switch alarm
A04
Definitive lockout
NTC domestic water fault (R.S.I. only with external water tank with probe)
A06
Signal
NTC heating delivery fault
A07
Temporary stop
Heating delivery probe over-temperature
Temporary then definitive
Delivery/return line probe differential alarm
Definitive lockout
NTC heating return line fault
A08
Temporary stop
20 R.S.I.:
low temperature system thermostat alarm
Temporary stop
Heating return line probe over-temperature
Temporary then definitive
Outlet/return line probe differential alarm
Definitive lockout
Cleaning the primary heat exchanger
A09
Signal
NTC flue gases fault
Temporary stop
Flue gases probe over-temperature
Temporary then definitive
Parasite flame
A11
Temporary stop
25 C.S.I. - 30 C.S.I./R.S.I.:
low temperature system thermostat alarm
A77
Temporary stop
Temporary pending ignition
80°C flashing
Temporary stop
Water pressure switch intervention
flashing
Temporary stop
Calibration service
ADJ
Signal
Calibration installer
Chimney sweep
ACO
Signal
Vent cycle
Signal
Pre-heating enabled (only C.S.I.)
Signal
Preheating heat request (only C.S.I.)
flashing
Signal
External probe presence
Signal
Domestic water heat request
60°C
Signal
Heating heat request
80°C
Signal
Antifreeze heat request
Signal
Flame present
Signal
- while the boiler is powered up, using a small screwdriver included,
press the CO button (fig. 42) for at least 4 seconds, to check the
meter has been reset, power down then power up the boiler; the
meter reading is shown on the monitor after the “-C-” sign.
b
Live electrical parts.
Note:
the meter resetting procedure should be carried out after each
indepth cleaning of the primary exchanger or if this latter is replaced.
To check the status of the total hour meter, multiply the reading by 100
(e.g. reading of 18 = 1,800 total hours; reading of 1 = 100 total hours).
The boiler continues to operate normally even when the alarm is
activated.