18
ENGLISH
Mynute Boiler 24/45 B.S.I.
Pipe length
ø 80-125 [m]
Flue gas
flange (F)
Load losses for each
bend (m)
45°
90°
up to 2,5
Ø 42
1,35
2,2
from 2,5 to 10,5
not installed
Mynute Boiler 28/60 B.S.I.
Pipe length
ø 80-125 [m]
Flue gas
flange (F)
Load losses for each
bend (m)
45°
90°
up to 2,5
Ø 44
1,35
2,2
from 2,5 to 8,5
not installed
outside temperature (°C)
tube
lenght
(m)
NON COMPULSORY
CONDENSATE BASIN
COMPULSORY
CONDENSATE BASIN
Max pipe length ø 80-125 Mynute Boiler 28/60 B.S.I.
TWIN OUTLETS (ø 80) (fig. 10)
Twin outlets can be placed in the most suitable direction according
to the room requirements.
The air inlet adaptor must be correctly oriented, it is therefore
necessary to fix it using the appropriate screws, so that the
locating tab does not interfere with the casing.
When necessary, the flue gas flange (F) must be removed using
a screwdriver as a lever. The table indicates the permitted linear
lengths. According to the length of the pipes used, it is necessary
to insert a flange, selecting one from those contained in the boiler
(see the following table).
Mynute Boiler 24/45 B.S.I.
Pipe length
ø 80 [m]
Flue gas
flange (F)
Load losses for each
bend (m)
45°
90°
up to 4+4
Ø 42
1,2
1,7
from 4+4 to 20+20
not installed
Mynute Boiler 28/60 B.S.I.
Pipe length
ø 80 [m]
Flue gas
flange (F)
Load losses for each
bend (m)
45°
90°
up to 2+2
Ø 44
1,2
1,7
from 2+2 to 17+17
not installed
separately (1856/1)
C82-C82x
Discharge via
single or common smoke
pipe and wall suction line
C92-C92x
Discharge on
roof (similar to C33) and
air suction from a single
existing smoke pipe
0
5
10
15
20
25
30
35
0
5
10
15
20
25
30
35
40
45
50
55
B22P/B52P
Suction indoors and discharge outdoors
C12-C12x
Discharge via concentric wall outlet. The pipes may leave the
boiler independently, but the outlets must be concentric or sufficiently
close together to be subjected to similar wind conditions (within 50 cm)
C22
Discharge via concentric outlet in common smoke pipe (suction and
discharge in the same pipe)
C32-C32x
Discharge via concentric roof outlet. Outlets as for C13
C42-C42x
Discharge and suction in common separate smoke pipes, but
subjected to similar wind conditions
C52-C52x
Separate discharge and suction lines on wall or roof and in ar-
eas with different pressures. The discharge and suction lines must never
be positioned on opposite walls
C62-C62x
Discharge and suction lines using pipes marketed and certified
Rear outlet
exhaustion lenght
(m)
Mynute Boiler 24/45 B.S.I.
Max pipe length ø 80
lenght of the intake duct
(m)
no flue
gas
flange
flue
gas
flange
ø 42mm
Mynute Boiler 28/60 B.S.I.
Max pipe length ø 80
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
lenght of the intake duct
(m)
exhaustion lenght
(m)
no flue
gas
flange
flue
gas
flange
ø 42mm
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
10,5
11,0
11,5
12,0
12,5
13,0
13,5
14,0
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
outside temperature (°C)
tube
lenght
(m)
NON COMPULSORY
CONDENSATE BASIN
COMPULSORY
CONDENSATE BASIN
Max pipe length ø 80-125 Mynute Boiler 24/45 B.S.I.