45
METEO GREEN HE R.S.I.
The relative domestic hot water temperature is automatically as-
signed to each time band set in the HOTW-PROG menu (T-DHW
1, 2, 3):
T-DHW1
T-DHW2
T-DHW3
The default domestic hot water temperatures are set for 50°C,
but you may adjust them as already explained in paragraph 3.2.4
“Description of menus”, “USER” dedicated section. If the domestic
?' \'[^ '[>|[^\'`^[ [^[ |[^?&\]<[@ >?@<[@
'[ |^?^\>
are assigned these new values.
EXAMPLE OF PROGRAMMING
We consider that you want to set three heating time bands in 24
hours.
- time band 1 from 6.30 to 8.30
desired temperature 45°
- time band 2 from 12.00 to 15.00
desired temperature 50°
- time band 3 from 17.00 to 23.00
desired temperature 48°
In PROGR-RISC MENU set the time bands.
In USER MENU set the desired temperature:
T-DHW1 45°C
T-DHW2 50°C
T-DHW3 48°C
The progress of temperature/time bands will be as shown in the dia-
gram.
You may set even temperatures for different time bands
Eg. T-DHW-1 = T-DHW-2
It is not possible to overlay the time bands.
The time bands programming phase always begins with a starting
'<>['\{][
<@[&'<[@<''[>{?]
\&@&<[<'\&
[&@<&'<>['\{][
<@[&'<[@<''[>{?] .
The 3 time bands are expressed on the display by the following
symbols:
1)
ON OFF
2)
ON
OFF
3)
ON
OFF
Set the starting timetable (ON) by pressing the + and – buttons and
'[|^['??&^>
[@<|]\\||[\^\<&`^[
Set the ending timetable (OFF) by pressing the + and – buttons and
'[|^['??&^>
During the OFF phase, the preparation of domestic hotwater is
stopped.
Once you set down the ending timetable, press ENTER.
[@<|]\\||[\^\<&`^[
Proceed the same way to set the subsequent time bands
,
.
}'[^ ?` &<[@ |^?^\>><&
|^[ '[ ?^ {`''?& '? ? '?
RETURN and exit the HOTW-PROG menu.
To stop at any moment the time bands programming, close the
cover of the panel.
The values set will not be memorized.
You may exclude the heating schedule from one or more time ban-
ds. To do so, proceed as follows:
- set a time band: example
ON -
OFF as previously
indicated
- press ENTER
- for the second time band overtake the 24 hours by pressing the
+ button.
The display shows segments instead of the timetable, see the
`^[
|^['??&^>
By doing this operation, you
excluded the second time
band
from the heating schedule
- for the
third time band
overtake the 24 hours by pressing the +
button
The display shows segments instead of the timetable.
|^['??&^>
By doing this operation, you
excluded the third time band
from the
heating schedule.
The boiler will operate according to the time band set and will stay
off the rest of the time.
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
T-ACS2
T-DHW2
T-ACS1
T-DHW1
T-ACS3
T-DHW3
34
36
38
40
42
44
46
48
50
6.30
8.30
12.00
15.00
17.00
23.00
ON
OFF
ON OFF
ON OFF
fasce orarie/time bands
temperature/temperatures
°C
ora/
hour
fascia 1
time band 1
fascia 2
time band 2
fascia 3
time band 3