INSTALLATION

7

12  WATER CONNECTIONS

AD

N

N

A

B

C

D

E

F G

H

I

L

M

A

B

C

O D

P

E

F

Q

G H

I

L

M

O

DF

AD

IDRA DS 

1000

AD

IDRA DS 

750

IDRA DS 200 - 550

IDRA DS 750 - 1000

UAC

MC

Psc

RL

RC

M

Psr

R

EAF

UAC

MC

Psc

RL

RC

M

Psr

R

EAF

DF

DESCRIPTION

IDRA DS

200

300

430

550

750

1000

UAC 

Domestic hot water outlet

1” M

1"1/4 M

Ø

MC 

Outlet from boiler

1” M

1” M

Ø

RC 

Return to boiler

1” M

1” M

Ø

Outlet from solar collector

1” M

1” M

Ø

Return to solar collector

1” M

1” M

Ø

RL 

DHW recirculation

1” M

1” M

Ø

EAF (SB)  Domestic cold water inlet

1” M

1"1/4 M

Ø

Psc 

Diameter/length of boiler sensor socket

18/180

16/180

mm

Psr 

Diameter/length of solar controller sensor socket

18/180

16/180

mm

AD 

Quantity/diameter/length of magnesium anode

1/33/450 1/33/450 1/33/520 1/33/520 1/40/600 1/40/600 mm

DF 

Flange internal diameter

130

130

130

130

130

130

mm

A

171

171

208

207

75

75

mm

B

243

253

329

348

289

289

mm

C

403

393

427

443

428

421

mm

D

598

693

684

788

799

834

mm

E

738

903

824

1088

969

1006

mm

F

878

1113

964

1328

1144

1337

mm

G

953

1233

1064

1428

1234

1426

mm

H

1029

1323

1174

1538

1321

1506

mm

I

1098

1438

1289

1653

1444

1637

mm

L

1170

1670

1440

1784

1707

2032

mm

M

1338

1838

1644

1988

1846

2171

mm

N

Ø 604 Ø 604 Ø 755 Ø 755

Ø 

1000

Ø 

1000

mm

M8 threaded inserts for grounding point/accessory han-

dles connection

700

700

700

700

600

600

mm

P

-

-

-

-

555

-

mm

Q

-

-

-

-

-

1237

mm

It is recommended to install shut-off valves at domestic water inlet and outlet.

Check the efficiency of the seals when filling/refilling the storage cylinder.

In case of a probe, any electric junction between probe cable and extensions for the connection to the electric panel must be 

soldered and protected with a sheath or a suitable electric insulation.

Summary of Contents for IDRA DS 200

Page 1: ...Installation and Operation Manual IDRA DS 200 300 430 550 IDRA DS 750 1000 Solar solar storage cylinder IDRA DS Installation and Operation Manual EN ...

Page 2: ... is not going to be used for an extended period of time contact the manufacturer s Technical As sistance Centre to have at least the following operations performed Close the shut off cocks for the domestic hot water circuit Shut down the boiler connected to the storage cylinder as instructed in its own manual Switch the storage cylinder OFF at the control panel if fitted and at the mains power swi...

Page 3: ...ation made of expanded polyurethane free from CFC chlorofluorocarbons a flange is provided for easy cleaning and maintenance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA DS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON SOLAIRE Modele Model Fabrication Code Année bar W l W kW l 1 BOLLITORE SOLARE Mode...

Page 4: ...1 38 1 53 1 33 1 51 2 09 2 24 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 50 50 kW 400 572 774 774 1240 1240 l h 70 C T 20 C 10 3 17 20 7 20 7 38 38 kW 247 425 505 505 930 930 l h 60 C T 20 C 6 5 11 15 5 15 5 25 25 kW 160 277 375 375 620 620 l h 50 C T...

Page 5: ... heater pre heated to the indicated temperature considering an in crease of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation tank lower part 70 C 374 438 659 863 1190 1530 l 60 C 284 375 531 675 877 1110 l 50 C 205 310 390 485 762 790 l Integration coil probe point reference Vbu reference volume Solar coil probe reference Pressure dr...

Page 6: ...h open Apply the upper insulation 2 and the upper cover 5 use a spatula if the cover application on the protection plate proves difficult Close the interlocking flaps L completely which were previously left with an open tooth If disassembling is required proceed in reverse order 4 5 2 1 3 3 1 1 3 L 3 L b Wear suitable personal protective equipment and use suitable safety devices 9 PLACE OF INSTALL...

Page 7: ... 40 600 1 40 600 mm DF Flange internal diameter 130 130 130 130 130 130 mm A 171 171 208 207 75 75 mm B 243 253 329 348 289 289 mm C 403 393 427 443 428 421 mm D 598 693 684 788 799 834 mm E 738 903 824 1088 969 1006 mm F 878 1113 964 1328 1144 1337 mm G 953 1233 1064 1428 1234 1426 mm H 1029 1323 1174 1538 1321 1506 mm I 1098 1438 1289 1653 1444 1637 mm L 1170 1670 1440 1784 1707 2032 mm M 1338 1...

Page 8: ...ly cocks in the domestic water circuit are all open Switch the electricity supply ON at the mains power switch and at control panel switch if fitted 15 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heater temperature control where available to the minimum value b If the ...

Reviews: