System layout

SYSTEM LAYOUT

1097
1048

1818

49

70

Collector

probe socket

Collector

outlet

Collector

return

(*)

(**)

Direction of flow of

heat transfer liquid

(*)   Alternative 

 

collector return

(**) Alternative 

 

collector outlet

Ventilation 

holes

Glass 3,2 mm.

Connector 

Ø 22 mm.

b

  The outlet and the return 

must be connected to 

opposite sides.

Connection

ring nut, 1"

Identification

IDENTIFICATION

CODICE :          

20075477

TIPO : CP20TSS

S/N : 

COLLETTORE SOLARE PIANO

DIMENSIONI: 1818X1048X70 mm

SUPERFICIE LORDA: 1,91 m

2                               

                             

TEMPERATURA DI STAGNAZIONE: 192°C 

SUPERFICIE DI APERTURA: 1,78 m

2           

                             

CONTENUTO LIQUIDO: 1,6 l

SUPERFICIE ASSORBITORE: 1,77 m

2  

                             

PESO A VUOTO: 34 kg

LIQUIDO TERMOVETTORE:

 

ACQUA+GLICOLE PROPILENICO

MAX CONCENTRAZIONE GLICOLE: 50%

MAX PRESSIONE ESERCIZIO: 10 bar

FABBRICATO IN ITALIA da Riello S.p.A.

20075510_E3

EN 12975

Certif. 011-7S2400F

13000000

BAR CODE 128B

Anno di produzione

SERIALE PROGRESSIVO

Code

Year of production

Serial Number

Description

Flat plate 

solar collector

Dimensions

Gross area

Aperture area

Absorber area

Empty weight

Maximum operating pressure

Stagnation temperature

Liquid content

Max glycol concentration

Heat transfer fluid:

water+propylene glycol

Data label

To be applied to the back of

the solar collector on installation

Serial number plate

by Riello S.p.A.

Made in Italy

Data plate

Codice . . . . . . . . 
Modello . . . . . . . 
Matricola . . . . . . 

Tipo . . . . . . . . . . . . . . . . . . . . . . . 

Codice . . . . . . . . . . . . . . . . . . . . . 

Dimensioni. . . . . . . . . . . . . . . . . . 
Superficie lorda . . . . . . . . . . . . . . 
Superficie di apertura . . . . . . . . . 
Superficie assorbitore . . . . . . . . . 
Peso a vuoto . . . . . . . . . . . . . . . . 
Massima pressione di esercizio . 
Temperatura di stagnazione . . . . 
Contenuto liquido . . . . . . . . . . . . 

COLLETTORE SOLARE (neutro)

Massima concentrazione glicole . 

FABBRICATO IN ITALIA da Riello S.p.A.

Liquido termovettore . . . . . . . . . . 

COLLB1_IT

Serial N°

Model

Code

 

b

If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper installation 

and servicing may be rendered difficult.

Summary of Contents for 20095379

Page 1: ...SCF 20B Solar Solar Collector EN Installation manual Installation manual...

Page 2: ...mals caused by improper installation adjustment maintenance or use Range MODEL CODE SCF 20B 20095379 SCF 20B Pack of 2 20095380 SCF 20B Pack of 7 20095381 RANGE Contents CONTENTS The following symbols...

Page 3: ...011 7S2400F 13000000 BAR CODE 128B Anno di produzione SERIALE PROGRESSIVO Code Year of production Serial Number Description Flat plate solar collector Dimensions Gross area Aperture area Absorber area...

Page 4: ...scription U M IAM 50 0 87 Efficiency col 58 Tested according to EN 12975 referred to a 33 3 water glycol mix flow rate of 140 l h and irradiation G 800W m2 Tm Coll _inlet _temp Coll _outlet_temp 2 T m...

Page 5: ...e heat exchanger must be the one near the sensor pocket of the last collector of the line The connection with the circuit that comes back from the heat exchanger must be at the bottom of the first col...

Page 6: ...4 4 8 11 10 12 7 5 20 M 9 C 6 T M 2 Solar Regolator 17 15 16 18 3 R 1 1 19 19 Water control system 13 14 b b If copper pipes are used joints must be hot brazed b b We recommend the use of stainless st...

Page 7: ...em into service im mediately A B 1 1 Handling HANDLING Remove the PVC wrapping to free the solar collector from the pallet Apply the data label provided in the document enve lope to the back of the so...

Page 8: ...cted against damage by the weather and birds and animals Angle of collectors General Solar collectors are designed to be installed at angles of between 15 minimum and 75 maximum Make sure that the ble...

Page 9: ...lar circuit at ambient temper ature with the collectors shielded from the sun s rays 1 Open the non return valve A 2 Open the air vent at the highest point in the system see figure alongside and keep...

Page 10: ...ery two years MAINTENANCE Collector circuit Cold circuit pressure ____bar see table above Collector circuit seal test Safety valve check Anti freeze checked to ___ C pH of heat transfer fluid ____ Col...