25
Operation
6006113_0 – 12.11.2021
EN
4.6.7
Ceiling connection with effect lighting
If the extractor hood is equipped with a ceiling connection
with effect lighting, the lighting may be controlled as follows.
☞
Press the slider at the position below the
symbol to switch the effect lighting of the
ceiling connection on or off.
4.6.8
Extraction mode / recirculated air mode
changeover
If the extractor hood is configured for hybrid mode, it is
possible to switch between extraction mode and recirculated
air mode at any time after activating the changeover
function.
The changeover function is activated in the extractor hood
configuration mode.
Observe the extractor hood instructions.
If the changeover function is activated:
☞
Press the slider at the position below the
symbol.
Button glows dimly:
y
The extractor hood operates in exhaust air
mode.
y
The wall box is opened.
y
The cleaned air is discharged outdoors.
Button glows brightly:
y
The extractor hood operates in recirculated
air mode.
y
The wall box is closed.
y
The cleaned air is discharged into the
room.
4.6.9
Filter filling indicator
The device has a check indicator in order to remind the
operator to change the filter filling. If no recirculated air filter
is used, the control indicator does not have any meaning.
The function is set so that the button flashes every 1,000 fan
operating hours (flash duration 120 seconds) as soon as the
extractor hood is turned off. The hours counter is restarted by
switching off the control indicator.
Button flashes:
The filter filling must be replaced.
Observe the extractor hood instructions.
☞
Press the slider at the position below the
symbol (> 1 second) to restart the hours
counter.
4.6.10 Window contact switch
If a window contact switch is connected to the extractor
hood, this monitors whether the corresponding window is
open or closed. Extraction only takes place with an open
window or in recirculated air mode.
Button flashes:
y
A window contact switch is connected to
the extractor hood.
y
The window is closed.
y
The extractor hood does not perform
extraction.
☞
Open the window.
y
Extraction can be used.
4.6.11 AutoRun
Extractor hoods equipped with the AutoRun module start
automatically when the hob is turned on. When the hob is
switched off, the fan switches to the run-on function and
then switches off.
The AutoRun automation is set in the extractor hood
configuration mode.
Observe the extractor hood instructions.
Summary of Contents for Panorama BKF 90 iPP