Basics

 

Page 4 

 

1. Basics

 

 

 

WARNING AND CAUTION

 

 

WARNING

 

 

 

WARNING refers to possible injury to the user or significant damage to the meter if the user does 
not follow the procedures. 

 

 

CAUTION

 

 

 

CAUTION refers to restrictions and rules with regard to preventing damage. 

 

 

WARNING

 

 

Verify that all AC sources are disconnected before connecting or disconnecting the current 
transformer. Failure to do so will generate lethal voltages on the current transformer. 

 

If  you  are  not  knowledgeable  about  electrical  systems,  have  an  electrical  professional  install  this 
unit. The diagrams in these instructions pertain to the installation of the 600-ACSM and not to the 
overall wiring of the vessel. 

 

If an inverter is installed on the vessel, its power leads must be disconnected at the battery before 
the unit is installed. Many inverters have a ‘sleep mode’ in which their voltage potential may not be 
detectable with measuring equipment. 

 

If an inverter is installed on the vessel, it must be stopped and rendered inoperable before the unit 
is installed. 

 

Verify that no other DC or AC is connected to the vessels wiring before installing the unit. 

 

If the meter must be removed, connect the current transformer leads together before restoring 
power to the AC system. 

 

CAUTION

 

 

The back of the unit is not waterproof. Do not install where the back of the meter is exposed to 
water. 

Summary of Contents for 600-ACSM

Page 1: ...Page 1 BEP 600 ACSM AC SYSTEMS MONITOR Installation and Operating Instructions INST 600 ACSM_v2...

Page 2: ...Page 2 This page has been deliberately left blank...

Page 3: ...us Page 7 Onscreen Keyboard 8 Saving 9 Lock Unlock the Screen 9 Dimensions 10 2 INSTALLATION 11 Plug Information 11 Wiring Diagram 12 3 CONFIGURATION 13 AC Voltage 13 AC Current 14 Configuring Loadshe...

Page 4: ...hese instructions pertain to the installation of the 600 ACSM and not to the overall wiring of the vessel If an inverter is installed on the vessel its power leads must be disconnected at the battery...

Page 5: ...s Load shedding relay output with adjustable set point times Adjustable backlighting backlighting on with key press input for external dimming control Remote alarm output Load shedding relay input Spl...

Page 6: ...Chapter 1 Basics Page 6 Hardware Layout Screw Cover Screw Cover Escape button Up button Down button Enter button Socket A Socket B USB Socket...

Page 7: ...tton Brings up Main menu from any of the status pages Enters the desired selection from a menu Enters selected character on a calibration page Status Page A Status Page is the first screen that the me...

Page 8: ...accept Any existing labels will be overwritten by first character input Tip To quickly move selection box through the keyboard press and hold the Up or Down buttons Step 2 Repeat Step 1 until the requ...

Page 9: ...ettings file with these changes selecting no will keep the changes however the user settings file will not be overwritten and meter will revert back to last save on power up Note Refer to the Settings...

Page 10: ...Chapter 1 Basics Page 10 Dimensions 89 19 3 1 2 20 28 13 16 29 43 1 3 16 8 17 5 16 17 6 11 16 99 39 3 15 16 84 7 3 5 16 10 1 3 8 62 32 2 7 16...

Page 11: ...Chapter 2 Installation Page 11 2 Installation Plug Information...

Page 12: ...ATIVE BUS BAR REMOTE ALARM OUTPUT LOAD SHEDDING RELAY OUTPUT SNUBBER DIODE BACKLIGHTING CONTROL INPUT AC VSEN 4 VOLTAGE INPUTS 1 2 3 CT 10 3 CURRENT INPUTS 1 2 3 AC1 P V1 N V2 V3 AC2 P N C AC3 P N Wir...

Page 13: ...ut Calibration Step 1 Insert a ground wire into the pin of the input you are configuring Select Zero on the meter and then select Yes Step 2 Remove ground and then wire the Input AC Positive into the...

Page 14: ...ou need to alter the calibration follow the steps below Go to Main Menu Setup Input s Choose Current Input Calibration Step 1 Select Zero Ensure there is zero current then select Yes to confirm Step 2...

Page 15: ...of their AC loads Preventing a current rise to a level that will overload the ships generators and cause the Circuit Breaker to trip and lose power to all AC consumers Wire the Loadshed relay as per...

Page 16: ...Step 2 Use the soft keyboard to enter new timer value Step 3 When both the timers have been set you are able to Enable Load Shed at the Load shed function Alarms All inputs have the ability to have a...

Page 17: ...s Icon Colour Description Green Alarms Enabled No Alarm Active Red Alarms Enabled Alarm Active Grey Alarms Disabled Red or Green Alarms Muted Configuring Alarms All inputs have two alarm parameters th...

Page 18: ...oze This is a non selectable option When alarm is in snooze mode it will show the countdown of remaining snooze time Default Snooze Use this setting to change the default snooze time for selected inpu...

Page 19: ...rcentage between 0 100 100 being the brightest Backlight Timeout Level The backlighting level for when meter is running in Timeout Mode Set as a percentage between 0 100 100 being the brightest Backli...

Page 20: ...s at a predetermined hold time see below Hold Time The hold time is the time it takes for the meter to change from one Status Page to the next in Automatic Scroll mode Inputs Choose Main Menu Setup In...

Page 21: ...splay Type There are 2 Display Types that can be chosen from Not all Display Types are available on all inputs Text Gauge Below is a table showing what Display Types are available for each Input Type...

Page 22: ...ettings are modified and the save prompt window opens the password will need to be entered To set up a new password select Setup Password and then New Password The password will need to be entered twi...

Page 23: ...fault filename is user ini so this filename or a custom filename can be chosen Note If there is already a file with the same name on the memory stick please choose another filename Import Settings Sel...

Page 24: ...pletely Turn the meter supply off and then on again for a reboot Colour Test General colour test for LCD screen Factory Reset At any time the meter can be restored to a factory state This can be very...

Page 25: ...ght Mode Invert Status Pages Input s System Beep On Key Press Power Down Power Down Timeout Setup Password Simulation Mode Units Utilities InputConfiguration Type Label Status Page Display Type Alarm...

Reviews: