background image

Working principle: The microcomputer of the portable air compression massage system receives the 

information input by the user, the embedded software makes corresponding analysis 

operations according to the parameters selected by the user, starts each load through the 

drive circuit, and controls the air pump flow according to the parameters set by the user; 

then the pressure sensor collects The pressure signal is amplified, and the airbag pressure 

is controlled by the microcomputer after AD conversion.

Before use, please take out the product and wear it on the corresponding legs symmetrically, then 
turn  on  the  power  of  the  main  unit  and  adjust  the  appropriate  massage  gear  and  mode;  it  is 
recommended that the user maintain a comfortable and relaxed state, sit or lie down, and at the 
same  time  The  limbs  are  slightly  elevated  during  massage,  which  is  more  conducive  to  the 
lymphatic and blood circulation of the limbs.

1.  Push  the  ON/OFF  button  to  the  ON  position  to  turn  on  the  power  of  the  host  and  the  battery 
indicator light will be on;
2. Short press the gear/mode/standby button, the device enters the fatigue relief mode and starts to 
run in gear 1;
3. In the running state, every time you press the "Gear/Mode/Standby button", the gear will switch 
between 1-5 gears; when the equipment is running in 1-5 gears, long press the "Gear/Mode/Standby 
button" "1.5 seconds, when the gear returns to 0, the output stops and the output is in a standby 
state;
4. When the equipment is running in gears 1-5, quickly press the "gear/mode/standby button" twice 
within 1 second to switch the mode and change the mode indicator light;
5.  The  default  time  of  the  host  is  20  minutes,  when  the  host  runs  for  20  minutes,  it  will 
automatically stand by;
6. In any case, push the ON/OFF button to the OFF position to turn off the power of the host, and 
please turn off the power after use;

How it works

Preparation before Use

Operation Steps

10

9

How it works

Operation method

Pressure Sensor

Key operation

Indication display

Signal amplification

Microcomputer

Fault detection

Solenoid valve group

Microcontroller

Air pump speed control

During use, the user should remain in a relaxed state. If there is any discomfort during the 
treatment, they should stop using it immediately.

Note: The color of the indicator light corresponding to each mode
Blue: fatigue relief       Green: exercise recovery        Yellow: Deep Care

Summary of Contents for ACM-A1

Page 1: ...84215340 84215342 Fax 84215341 Postcode 610052 86 28 Scan the QR code to learn more User Manual ACM A1 Thank you for purchasing Beoka Air Compression Massager Before using this product please read the instructions carefully and keep it properly Executive standard Q 91510108629517429X 21 2020 The pictures in the manual is for reference only the product is subject to the actual product ...

Page 2: ...uality allowing users to relax under comfortable stress Introduction FCC Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device...

Page 3: ...ure 08 How it works 09 Preparation before Use 10 Operation Steps 10 Storage method 11 Operation method 10 Download the Applet 12 Device connecting 12 The equipment 13 Modes 13 14 15 12 Applet Maintenance 16 Repair 16 Suspected failure 17 Notes on disposal 18 Hazardous Substances and Content 19 16 Equipment maintenance Repair Conditions for Use Transportation and Storage 20 Product warranty 21 Warr...

Page 4: ...nge of the affected limb and timely ask the patient how they feel and adjust the massage gear in time according to the situation If symptoms and signs such as local subcutaneous hemorrhage or purpura ecchymosis or hematoma occur or discomfort such as pain paralysis chest tightness difficulty breathing dizziness etc occurs during the massage the use should be suspended and the doctor or agent shoul...

Page 5: ...use 13 People with skin diseases and infectious diseases are not easy to share a set of equipment and related accessories with others 4 Before the first use remove the battery case and charge it for about 1 5 hours to fully charge Connect the output end of the TYPE C cable to the DC charging port of the massager battery box and then connect the input end of the TYPE C cable to a mobile power suppl...

Page 6: ...battery in various harsh environments and The use of extreme operating conditions provides a very strong safety guarantee Product Name Air Compression Massager Model number ACM A1 Structural composition a host an integrated air bag a battery box a control system a display system an air pump and a pneumatic device The airbag is divided into L large M medium and S small Pressure range adjustable bet...

Page 7: ...bolism suitable for warm up before exercise and deep relief of muscle soreness after exercise the pressure is from the distal end to the proximal end the first step starts from the first chamber inflates in turn and moves backward every two chambers and the second step starts from the first and second chambers and every two chambers Continuously superimposed to 5 cavities two steps are alternately...

Page 8: ...on the device enters the fatigue relief mode and starts to run in gear 1 3 In the running state every time you press the Gear Mode Standby button the gear will switch between 1 5 gears when the equipment is running in 1 5 gears long press the Gear Mode Standby button 1 5 seconds when the gear returns to 0 the output stops and the output is in a standby state 4 When the equipment is running in gear...

Page 9: ...ill automatically jump to the registration device page the page will search for your device and display it on the interface 4 Click Connect after the connection is successful click OK to start using 5 To add new devices later you can add new devices in My My Devices Applets Device connecting 11 12 After using the product please fold it as follows Step 1 Fold and tile after decompression Step 2 Fol...

Page 10: ...arting from the first chamber and successively superimposed to 5 chambers each time to promote blood circulation of the lower extremities and relieve muscle fatigue suitable for long term standing or walking legs People with muscle soreness Workout recovery 14 Exercise recovery in one cycle the pressure goes from the distal end to the proximal end starting from the first chamber inflates deflates ...

Page 11: ...rter gently wipe the surface of the instrument with a smooth and soft damp cloth and do not put any liquid wine on the surface of the instrument Users should check the accessories regularly especially if the air bag is damaged Cleaning of the airbag The material of the airbag is TPU When cleaning it should be gently scrubbed with a warm water damp cloth and a mild detergent the temperature should ...

Page 12: ...can cause heating fire rupture and other phenomena The above conditions can cause heating fire rupture and other phenomena Do not throw it into the fire to overheat it Do not pierce with nails impact with gravity or conduct decomposition and transformation Do not connect the positive and negative electrodes of the battery directly with metal Please do not store it with necklace hairpin etc Please ...

Page 13: ...rature 5 40 Relative humidity 90 Atmospheric pressure 70kPa 106kPa Ambient temperature 50 Relative humidity 90 This product is suitable for automobiles trains ships airplanes and other modes of transportation During transportation it should be fixed to prevent violent vibration collision roll and fall and be upward careful light and rainproof No more than 5 layers of massager stacked 20 Environmen...

Page 14: ... to the qualified technical personnel identified by us 6 Ensure to continue to provide repair parts within 3 years after the production stop 7 Please refer to the host or packing box for the production date A failure caused by unauthorized disassembly and refitting of the product B failure caused by careless falling during use and handling C failure caused by lack of reasonable maintenance D failu...