Displaying percent values is done directly down to

0.001%. Smaller values come up in scientific notation

(example on the left hand side shows a value of

0.000012% as 1.2 E -05).

The composition of the combustable (carbon,

hydrogene, non combustables, details available at

your provider) is required to allow exact calculation.

Enter the values via configuration (refer to page 6).
By default the TM100 is set for liquid gas in bottles

(propane gas, LPG).

The basic model TM100 is available for rechargable

batteries (option; TM100x2 and TM100-o2 by

default). The rechargable model can be identified by

the charging socket (11).

Completely charge your TM100 before using it for the

very first time. Connect the TM100 with the mains

supply using the charging unit. LED indicator (10)

lights up at short breaks. The LED goes off of the

battery is fully charged. New NiMh type rechargable

batteries achieve their maximum capacity (lasts for a

couple of month’s operation) after the 3rd loading

cycle.

Depending on usage the supplied batteries last up for

years. Use size AA (Mignon) batteries only. Replace

batteries once the experation date is elapsed although

they provide power to avoid chemicals to poor out.

Carefully remove the head covers on upper and lower

side of the TM100 case using a screwdriver (3mm slot

type).
Put the TM100 on its keypad side and lift the bottom

side. Take out the battery holder and replace the

batteries. Assembling the TM100 is done in exactly

reverse sequence.
Never insert standard batteries in a TM100 with

charging option! Unintentional charging could

damage the device! Only use high quality NiMh

rechargable batteries if you have to replace them.

4

Charging

Changing Combustion

Composition

Replacing Batteries

(non rechargable models only)

Open TM100

LO BAT

LO BAT

Summary of Contents for TM 100

Page 1: ...TM 100 Operating Instructions Thermocomputer TM100 B A max grad on off inst charging B A ...

Page 2: ...ow 11 Charging socket rechargable option only Introduction 1 Safety Notes 1 Setup 1 Displaying Temperatures 2 Maximum Values 2 Absolute Maximums 2 Temperature Gradient 2 Cold Junction Temp Battery Voltage 3 TM100 O2 3 Changing Combustion Composites 4 Charging 4 Replacing Batteries 4 Opening TM100 4 Messages Display Codes 5 Error Messages 5 Configuration 6 Parameterlist 6 Technical Data 7 3 4 6 8 1...

Page 3: ...d this booklet carefully to become familiar with the various features and options of your new instrument Only connect the proper type of thermocouple to the TM100 to avoid damage of kiln and load due to wrong temperature indication When receiving TM100 and sensor as a package it is configured properly Never put your TM100 on top of a kiln Carefully insert the thermocouple plug into the socket 1 TM...

Page 4: ...ed when replacing batteries There it is an valuable indication in case of warranty disputes damage of kiln bricks etc The current increase of temperature gradient is a value of interest especially when firing gas kilns manually The value is shown in centigrade Celsius per hour positive on increasing temperatures or negative when kiln temperature drops Sudden changes in temperatures very large or v...

Page 5: ... uses a highly complex combustion formula to calculate all relevant atmosphere parameters oxygen O2 carbon monoxide CO carbon dioxide CO2 air gas ratio lambda To enable the TM100 this calculation some parameters of the combustable need to be entered in the configuration menue The temperature signal of the probe is connected to input A the O2 signal is lead to input B Due to physical laws an oxygen...

Page 6: ...ks The LED goes off of the battery is fully charged New NiMh type rechargable batteries achieve their maximum capacity lasts for a couple of month s operation after the 3rd loading cycle Depending on usage the supplied batteries last up for years Use size AA Mignon batteries only Replace batteries once the experation date is elapsed although they provide power to avoid chemicals to poor out Carefu...

Page 7: ...em inside the TM100 Contact us for assistance Error C1 internal check failed no further data acquisition Points to an internal problem of the signal converter Error C2 internal check found values to be inaccurate Might be caused by exceeding temperature range when water entered or electronic damage Error D1 hardware damage Contact us for repair Error D5 TM100 calibration data invalid loss of calib...

Page 8: ...er no P x while x stands for the parameter number Use keys 6 and 7 to adjust the selected parameter To choose another parameter use keys 4 or 5 again To save changes press and hold key 9 until display reads SET To cancel changes press and hold key 8 until display reads CAn Cancel 6 Configuration inst inst 9 A A 4 B B 5 or A A 4 B B 5 previous next parameter max max 6 grad grad 7 decrease resp incr...

Page 9: ... 0 c 2007 bentrup Industriesteuerungen D 35463 Fernwald Accuracy 0 1 refered to full scale Operating temperature range 15 to 55 C Storage temperature range 25 to 85 C Batterie lifetime about 2 years Alkaline Batterie lifetime rechargable about 6 months NiMh Loading time about 6 hours Maximum loading cycles 100 Charging power supply 9V AC 500mA Technical Data No Description Range Default Unit 7 Car...

Reviews: