9
Output range
Capacity
Gas volume at a min. Gas volume at a max
Max. inlet
Rated inlet pressures
kW
output Nm
3
/h
1)
output Nm
3
/h
1)
pressure mbar
mbar
BG550
G20 140-640
14,8
67,7
360
40
G25 140-600
17,4
74,4
360
40
G30 140-620
4,3
19,2
360
30-50
G31 140-620
5,7
25,4
360
30-50
BG550LN
G20 140-620
14,8
35,6
360
40
G25 140-620
17,4
76,9
360
40
BG650
G20 200-1125
21,2
119,0
360
40
G25 200-1125
24,8
139,6
360
40
G30 200-1125
6,2
34,9
360
30-50
G31 200-1125
8,2
46,0
360
30-50
Output range
TECHNICAL DATA
1)
Calorifi c value: kWh/m
3
15°C 1013.25 mbar (according to EN676)
2)
Dimension and capacity depending on gas quality and available pressure
Type
kWh/m
3 1)
kWh/kg
G20: Natural gas H
9,45
G25: Natural gas L
8,06
G30: Butane
32,24
12,68
G31: LPG
24,44
12,87
Connection
2)
Motor
Ignition transformer
BG550/BG550LN
Natural gas LPG 1
1/2”-2”
0,75 kW
230/400V 50 Hz
3,1/1,8A
Primary 230 V,
0,25A 50-60Hz 60VA
Sec. 11kV Ampl
50 mA rms
33% ED in 3 min
BG650
Natural gas LPG 1
1/2”-2”
1,5 kW
230/400V 50 Hz
5,7/3,3A
Primary 230 V,
0,25A 50-60Hz 60VA
Sec. 11kV Ampl
50 mA rms
33% ED in 3 min