9
Bentone
2.5 Recommended nozzle and pressure
Nozzle:
45° Solid/semisolid
60° Solid/semisolid
80° Solid/semisolid
Pump pressure
10 bar (8-25 bar)
depending on pump model
2.6 Burner installation
2.6.1 Hole patten
Make sure the hole pattern on the boiler is designed for burner flange.
Combustion
device
d
1
d
2
d
3
B 45A 2
ø (135) 165
M14
ø (200) 224-270
Because of the various boiler types with varying furnace geometries and
furnace loads, it is impossible to commit to a certain scattering angle or a
specific distribution pattern.
It should be noted that the scattering angle and distribution pattern changes
with pump pressure.
d
1
d
2
d
3
!
*NB It is important that
the spark does not strike
against the brake plate or
nozzle
2.4 Setting of brake plate and air flow
a
b
c
d
B45A 2
3,5-4,0
7,0-9,0
2,0-3,0
5,0-6,0
D
A
B
C