8
Bentone
165 205 86-3
2. Technical data
The burner is intended for:
• Light oil, B10 heating oil/biofuel blend, FAME, B-100 (RME) (as defined in DIN V51603-6).
and is used for:
• Water heating generators.
• Hot air generators (these require LMO 24 255 C2E).
2.1 Dimensions B 55-2/B 65-2
H
I
A
D
E
F
G
B
C
Type
Motor supply
Main supply
Sound
B 55-2
230/400V 3,1/1,8A
230V 0,38A 50Hz
89 dBA ± 0,5 dBA
B 65-2
230/400V 5,9/3,4A
230V 0,38A 50Hz
89 dBA ± 0,5 dBA
Max operating current, see data plate.
2.2 Electric Specification
Burner correspond to IP 20
Flame
tube measurement A
B 55-2
274
374
474
B 65-2
258
358
458
Ø B
Ø C
D
E
F
G
H
I
* J
160
155
610
321
400
405
304
609
200
* Min. recommended distance to floor.