background image

NOTICE

READ THE FOLLOWING BEFORE INSTALLING OR OPERATING EQUIPMENT.

Bently Nevada Corporation  h a s   a t t e m p t e d   t o  identify areas  o f  risk created
by improper installation  a n d / o r  operation  o f   t h i s  product.  T h e s e   a r e a s   o f  In—

formation  a r e   n o t e d   a s  WARNING  o r  CAUTION  f o r   y o u r  protection  a n d   f o r   t h e

safe  a n d  effective operation  o f   t h i s  equipment.  R e a d   a l l  instructions  b e f o r e
installing  o r  operating  t h i s  product.  P a y  particular attention  t o   t h o s e   a r e a s
designated  b y   t h e  following symbols.

/ \  WARNING

High voltage present
could cause shock
burns or death

Do not touch exposed
wires  o r  terminals

'CUITICDH

Machine  P r o t e c t i o n   C o u l d
Be Discontinued

IN THIS DOCUMENT PROCEDURES ARE GIVEN ONLY FOR ONE CHANNEL.
PROCEDURES FOR OTHER CHANNELS ARE SIMILAR EXCEPT FOR THE
OBVIOUS SUBS TI TU TION  O F  CORRESPONDING SWITCHES, TERMINALS,
AND INDICA TORS.

SYMBOLS

Special symbols  a r e  used  i n   t h e  manual  t o  illustrate specifics  i n   t h e  step—by—
step process.  F o r  example:

PRESS

FLASHING

CONNECT

DISCONNECT

TEST EQUIPMENT [Recommended)

Digital Multimeter

.1  II  0

0

6 , 3 5

4  1 / 2 —Digit Display
0  t o   1 0 0 0   Va c / V d c

0  t o   1 0   m e g o h m s

Power Supply

0 TO —50  V d c

OBSERVE  S C R E W D R I V E R

TK3 Calibration

Instrument

Gently Nevada  C o r p o r a t i o n

( 7 9 1

0

0

*co

ofI

 o°

TK3-2E  ( 1 2 0 / 2 2 0   Va c ,
5 0 / 6 0   H z )
TK3-2G  ( 4 0   t o   9 0   p s i

15  S t d   c f m   m a x )

15102

Summary of Contents for 3300/20

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...DOCUMENT NO 501 3300 20 DUAL THRUST POSITION MONITOR OPERATION MANUAL G E N T LY r 1 N E VA D A _ REV A B 11 1 A II 21154 8MARX 8 1NAR89 1 0 R i g i q I...

Page 3: ...operating t h i s product P a y particular attention t o t h o s e areas designated b y t h e following symbols WARNING High voltage present could cause shock burns or death Do not touch exposed wires...

Page 4: ...da Corporation l roximitor is a registered trademark of Bently Nevada Corporation Document No 80178 First Printing January 1988 Copyright 1987 Bently Nevada Corporation All Rights Reserved No part of...

Page 5: ...80178 01 D u a l Thrust Monitor Operation Blank Page iv...

Page 6: ...N DUAL THRUST MONITOR SYSTEM MONITOR FUNCTIONS 2 MONITOR OPTIONS 3 PROGRAMMABLE OPTIONS 4 OK 5 BYPASS 6 ALERT 7 DANGER MONITOR RANGES 9 READ CHANNEL THRUST POSITION 1 0 R E A D GAP VOLTAGE 1 I READ A...

Page 7: ...80178 01 D u a l Thrust Monitor Operation Blank Page vi...

Page 8: ...T ALERT li G A P A B U F F E R E D T R A N S D U C E R S rfn 6 6 5 6O n 6 6 3300 RACK E 11 CHANNEI A RECORDER 1O U T P U T ALE 3E1 C OrJTACT PROXIM1TOR PRO xlMimp I V A 1 1 0 1 w o o 1 1 1 4 1 1 1 0 0...

Page 9: ...first channel in the rack to go into alarm Pressing the RESET switch acknowledges the First Out ALARM RELAYS Monitor alarms can be programmed for either latching or nonlatching mode In the non latchi...

Page 10: ...0 2 0 3 11 AND 12 ONLY FOR RANGE OPTIONS 01 AND 11 00 NONE 01 5A EPDXY SEALED 02 5A HERMEtI CALLY SEALED 03 0UAD RELAYS EPDXY SEALED AGENCY APPROVAL OD 00 NOT REQ D 01 CSA 02 BASE Ir A 03 CITY OF LA...

Page 11: ...OR BY PA S1 1 OFT _ _ _ 0 OH i t 0 I1fv 11ING Al 5 Hz F 1 N ce EN cni IN IFF D DI 1RING a 1 1C TI SF I I Ai lij ROli Mi AGE I J E 1 1zil OH Dual Thrust Monitor Operation 5 O K i L s a O K 0 D A N C E...

Page 12: ...ER 5 I PA S S o SYSTEM IN POWER UP MODE MODE ED TJA S o I ISER INVOKE I r IF ST IN PROrEREEEE k n i n MANN I i 1 0 Lii PA _ a 11 ANNEL i OR I I 3 1 SSE_D BYPA T 0 Dual Thrust Monitor Operation 80178 0...

Page 13: ...kT 1 i01 pt i 1 TIVE A ON U I 1AIIIIFT r IN III I IV EI Y FIFIII r ALAPM IIVII IWO I IAI II I MAi I iil r II A1 1 NEMATl I IP 1 ONI I OtI WINO II I L i O N Dual Thrust Monitor Operation 7 A L E R T I...

Page 14: ...4 DANGER EIRST OUT CONDITION FOR RE 3PECTIVE A OR B CHANNEL THAT HAS EXCEEDED ALARN LEVEL TWO CHANNECI MA r INDICATE FIRST OUT FOLLOWING SELF TEST ON ON OFF OFF Dual Thrust Monitor Operation 80178 01...

Page 15: ...S 300 M I T I FU 1_ SCAT R A N G E 0 1 2 5 0 2 5 MIL 02 30 0 30 MII 4 1 i l L PalIL y 5 0 0 50 Mil 7 0 3 7 5 0 75 MILS MILLIMLTRES 12 1 0 1 minimr FRES MILLIMii PPS FOR JUMPf P PF DCPAMMIrls 1 1 1 1 1...

Page 16: ...Monitor Operation 80178 01 1 0 R E A D C H A N N E L T H R U S T P O S I T I O N 4 1 1 10P CON w o w A r rn JHrA If ME ADMI_D C o A AND H CHANNEL A C I CHANr lli L1 Df 3L 5 _ 5 THHUS I AP I1 1 N VAL...

Page 17: ...ation 1 1 R E A D G A P V O L T A G E L L T f c S GAP 7 WIJC i AN H E A D GAP VOl TACT FOR BOTH CHANNEL A AND HANI 1 I 0 Al M l Y 11 1 HENIER ME TFP SCALE BfAciS 0 D A N G E R G A P q A u l i R r o I...

Page 18: ...ETER SCALE BOTH NORMAL AND COUNTER SET POINTS ARE DISPLA YTD 0 BYP ASS D A N G E R A B U F F E R E D R A N S D U C E R S 0 R E A D D A N G E R S E T P O I N T L E V E L S I PRESSD A N G E RSWITCH AND...

Page 19: ...DURING CYCLIC SI I ST MONITORING IS ABOHE U UN TII IS PES01 VED 0 ERROR CODE S TOAD IN MEMORY AND FLASHED ON LCD B RGRAPH DISPLAY 0B Y P A S SLED GOES ON ANDO KLED FLASHES AT 5 H7 OIF ERROR IS IN FERM...

Page 20: ...OXIMATELY 3 0 SECONDS FOLLOWING A C T I O N 3 1 1 20 1 r 1 1 11 1 1PIISIM O N I T O R 0 IR 0 AI Pi C Nir MIR 9 fli ANSDUCIfr NOil Al I11011011 H O W 110MH1 HAR0PAL1 I 1 LA 1 1 I RI 1R ONLY 111E SUM HI...

Page 21: ...TOLERANCE 4 7 5V NODE OUT OF TOL RANCE I N O D E OU I OF TO I RANCE 4 M 6 5 V N O D E O U 1 O r TOI_I 1 1011 E 4 1 5V NODE OUT O r FOL EP AI sciC CLOCK FAILURE 44 RAM FAILURE IC U4 OUTPUT DISAGREES WI...

Page 22: ...al Thrust System 1 M Monitor Functions Monitor Options 3 Monitor Ranges 8 0 Options Programmable 3 Monitor 3 p Programmable Options 3 R Read Alert Set point levels 1 Read Danger Set point levels 1 1 R...

Page 23: ......

Page 24: ...3300 20 DUAL THRUST POSITION MONITOR MAINTENANCE MANUAL B E N T LY NEVADA...

Page 25: ...ns or death Do not touch exposed wires or terminals CUITICDH Machine Protection Could Be Discontinued IN THIS DOCUMENT PROCEDURES ARE GIVEN ONLY FOR ONE CHANNEL PROCEDURES FOR OTHER CHANNELS ARE SIMIL...

Page 26: ...Proximitor is a registered trademark of Bently Nevada Corporation Bently Nevada Part No 80179 01 First Printing November 1987 Revision H June 1990 Copyright 1987 1990 Bently Nevada Corporation All Ri...

Page 27: ...80179 01 D u a l Thrust Monitor Maintenance Blank Page iv...

Page 28: ...P VOLTAGE 1 1 READ ALERT SETPOINT LEVELS 1 2 READ DANGER SETPOINT LEVELS 1 3 SELFTEST 1 4 DISASSEMBLY PROCEDURE 1 5 FRONT PANEL ASSEMBLY REMOVAL 1 6 SIGNAL INPUT RELAY MODULE 1 7 INSTALLED PROGRAMMABL...

Page 29: ...LE S E C T I O N ALARM SETPOINT ADJUST 2 5 CHANNEL BYPASS 2 6 DANGER BYPASS 2 7 TEST CHANNEL ALARMS 2 8 CALIBRATE CHANNEL 2 9 TEST OK LIMITS 3 0 ZERO VOLT ADJUST 3 1 FIELD WIRING DIAGRAMS 3 2 RECOMMEN...

Page 30: ...O R O O K 0 O DANGER 0 A0ALERT 0 B O BYP ASS 0 D A NR A L E R T 00 60th e a 6 a n 0 0 11 M f t 3300 RACK CHANNEL A RECORDER OUTPUT osaalloll 111w ALERT RELAY CONTACTS PROXIMITOR PROXIMTOR CHANNEL A P...

Page 31: ...he first channel in the rack to go into alarm Pressing the RESET switch acknowledges the First Out ALARM RELAYS Monitor alarms can be programmed for either latching or nonlatching mode In the non latc...

Page 32: ...3 4 0 0 4 0 MILS 05 0 5 0 MILS I 0 6 7 5 0 7 5 MILS I 11 0 5 0 0 5 MILLIMETRES 2 1 0 1 MILLIMETRES 1 3 2 0 2 MiLLJME TRES 01 7200 PROYAA 7 P C r r i O N E ZCO rnv miL 2 EPOY r 3 2 1 4 n OR I P R C B...

Page 33: ...ANSDUCERS NOT OK OR BY PASSED OFF OK 0 FLASHING AT 5 H z ERROR EN COUNTERED DURING CYCLIC TEST READ ERROR MESSAGE S E E 1z ON Dual Thrust Monitor Maintenance 5 O K O AO 0 O K D A N G E R A L E R T B Y...

Page 34: ...0 0 DANGER 0 AOALERT C B BYP ASS I LED DISPLAY A CON HON B Y P A S S o MONITOR IN DANGER BYPASS MODE o SYSTEM IN POWER UP MODE o USER INVOKED SELF TEST IN PROGRESS o BOTH CHANNEL BYPASS 0 B Y P A S S...

Page 35: ...DITION FOR RESPECTIVE A OR B CHANNEL THAT HAS EXCEEDED ALARM LEVEL TWO CHANNELS MAY INDICATE FIRST OUT FOLLOWING SELF TEST ON _ 03 A L E R T 0 ON Dual Thrust Monitor Maintenance 7 A L E R T 1 1 1 1 1...

Page 36: ...171 O N ON ON AND VOTING OFF OFF ON FIRST OUT CONDITION FOR RESPECTIVE A OR B CHANNEL THAT HAS EXCEEDED ALARM LEVEL TWO CHANNELS MAY INDICATE FIRST OUT FOLLOWING SELF TEST ON OFF ON OFF IF EITHER CHA...

Page 37: ...SCALE RANGE 0 1 2 5 0 2 5 MILS 0 2 3 0 0 3 0 MILS 0 3 4 0 0 4 0 MILS 0 5 5 0 0 5 0 MILS 0 6 7 5 0 7 5 MILS 11 0 5 0 0 5 MILLIMETRES 12 1 0 1 MILLIMETRES 1 3 2 0 2 MILLIMETRES SEE 23 FOR JUMPER PROGRAM...

Page 38: ...ance 80179 01 1 0 R E A D C H A N N E L T H R U S T P O S I T I O N MCNP DR CONTINUOUc sLY INDICATES MEASURED THRUST POSITION VALDES OR C ANNE I S A AND 8 CHANNEL A PROBE A i D ENEEI CHANNEL B PROBE T...

Page 39: ...V O L T A G E H 77S GAP S ilmOLH G A P VOLTAGE FOP BOTH CHANNEL A A N D H N N E _ 7 4 VETEP M E T E R SCALE CHANNEL A PROBE z CID 1 CHANNEL B PROBE A L E R T u 0 BYP ASS 0 D A N G E R A P A B U F F E...

Page 40: ...H C L 4 7 R z ETPOINTS E 0 7 7 D A N C E R re A B W A S S 0 i A P A L L R I S U F F E R E D T R A N S D U C E R S 0 1 3 R E A D D A N G E R S E T P O I N T L E V E L S PRESSDANGER SWITCH A N D READ DA...

Page 41: ...RS ARE DETECTED DURING CYCLIC SELF TESTS o MONITORING IS ABORTED UNTIL THE ERROR IS RESOLVED o ERROR CODE STORED IN MEMORY AND FLASHED ON LCD BARGRAPH DISPLAY oB Y P A S SLED GOES ON AND O KLED FLASHE...

Page 42: ...0 C DANGER 0 A 0 ALERT O B 0 KISS 0 u A N C I R anti B U F F E R E D T R A N S D U C E R S 0 NOTE ALTHOUGH BOTH COLUMNS ON BARGRAPH FLASH ERROR CODE IS ONLY THE SUM OF BARGRAPH SEGMENTS DISPLAYED IN O...

Page 43: ...OF TOLERANCE VRL NODE OUT OF TOLERANCE 1v1 1iREF 6 5V NODE CUT OF TOLERANCE 7 u H 010F SUT OF TOLERANCE RAM C U 4 D U TPU P V O L T A G E VAL1JF TESTED ONLY AT POWER UP OR USER INVOKED SELF TEST ERRO...

Page 44: ...STANDOFF 4 PLACES SIDE COVER REMOVE SIDE COVER B Y PINCHING PROTRUDING TIP ON EACH STANDOFF FOR DETAIL OF FRONT B A C K P L A N E PANEL ASSEMBLY SEE M O N I T O R FRONT PANEL 16 CONNECTORS 2 d 8294 3...

Page 45: ...L RETAINING SCREW S P R I N G WASHER RIBBON CABLE SLIDING STANDOFF R294 P 11P 39 GTP 49 R14 2 c o p 2 9 5 1 TP4 4 3 SW1 B TP8 0 w 1 1 V TP47 B TP18 TP16 TP5 8 W20 A K c i W15 W 19 W3 g E g A 2 1 4 E...

Page 46: ...ould cause shock burns or death Do not touch exposed wires or terminals JUMPERS W I W8 m o t 1 0tRONONO O a u 1 1 4 1 1 1111 1 101 1 1 101 1 1 1 1 1 1 1 1 1 1 0 FM 0 1 1 I IFC 0 a e We L 2 W7 0 0 WS 0...

Page 47: ...nance 1 7 S I G N A L I N P U T R E L A Y M O D U L E S C O N T WARNING High voltage present could cause shock burns o r death Do not touch exposed wires o r terminals ONAL N P U T l 1 0 n U l m a y o...

Page 48: ...RANGE AS ORDERED o OK MODE AS ORDERED o TRANSDUCER INPUT AS ORDERED o DANGER BYPASS DISABLED o NORMAL DIRECTION TOWARD PROBE R294 c I 1 39 OTP 49 SW1 W15 X 9_9 0 TP8 W 3 Cal A 2 1 4 4 S 1 6 1 6 9 1 1...

Page 49: ...P O N S E T I M E iRSI OUT LNABLED 0 DISABLED I JUM INSTALLED Wi 6A PERS REMOVED W16A P TT LOCA 1 10i W19 ARM DELAYS 0 1 SECOND o 1 SECOND o 3 SECONDS 0 6 SECONDS JUM INSTALLED W15B W15A Wi 5A B PERS...

Page 50: ...ED REMOVED INSTALLED REMOVED o LATCHING W15C o LATCHING W16B o NON LATCHING W15C o NON LATCHING _ _ _ W16B DANGER VOTING OK MODE JUMPERS JUMPERS INSTALLED REMOVED INSTALLED REMOVED o AND W16C o LATCHI...

Page 51: ...d c 4 JUMPERS I N S TA L L E D W7B D _ WBD F W9A B REMOVE A L L JUMPERS FROM W7 W8 W9 W10 W11 A N D W12 W11D F THEN REINSTALL ACCORDING TO TABLE W12B D NORMAL DIRECTION JUMPERS M i i g16 aii n n W18...

Page 52: ...CALE OPTCN C DETAIN METER SCALE FROM REAR 1 N U A L AND INSERT N FRONT PANEL AC SHOWN To ENSURE CORRECT 7ITTINC AND ALIGNMENT THE METER SCALE MUST BE CUT FROM THE PLASTIC SHEET EXACTLY ALONG THE MARKE...

Page 53: ...W2A W2A W2C W2A W3F W3E W3D W3F W3D W4D E W4D F W4D E N4D E W4D E W5C F W5C F W5C F W5C F W5C F W6B W6A W6B W6B W6B 7200 SERIES 1 1 m m 100 m V M I L W2C W2C W2C W2A B W2B W2A B W2C W2A W3A W3E W3B W...

Page 54: ...O vE T O R FROM RACK A i iD F FMO vE SIDE COVER S E E 5 J3 CONNECTOR fa 7 J 2 1 J moNITDRING S LsC NT Ni ED JUMPERS WHILE MONITOR I s Fin lovED FROM RAnK VIEW SHOWING EXPANDER BOARD REMOVED JUMPERS MU...

Page 55: ...NTs PRESS AND HOLDALERT DPD A N G E R SWITCH ON FRONT PANEL Et OR SWITC HES ON SYS TEM T O ADJUST S7TPT i r AN RESET AA OR AB SET SWITCH CLOSE O N NEL r a 3300 01 1 131W C H T C A 3 u P P L I E S T R...

Page 56: ...BB CHANNEL B Y S W I T C H TO ON RESPONDING BYPASS HE 1 CES CN OK LED DOES CEr AND AM LTUDE r I 1rr MACHINE PROTECTION WILL BE LOST WHILE CHANNEL BYPASS IS ON NOTE WHEN CHANNEL BYPASS IS SWITCHED ON C...

Page 57: ...ASS SWITCH CAN B E DISABLED BY A F U R R E D I R A N S D O C E R S DANGER BYPASS DEFEAT SEE 21 Dual Thrust Monitor Maintenance 2 7 D A N G E R B Y P A S S N4I _ 2 _ 1 L i N J mAcHINE PROTECTION WILL B...

Page 58: ...A N A49 01 lirmicow M U R E C ICII 1 1 1 1 SIGNAL INPUT RELAY MODULE _ POWER SUPPLY DISCONNECTcON AND N WIRING FROM CHANNEL A TERMINALS ON SIGNAL INPUT RELAY MODULE 2 CONNECT MULTIMETER AND POWER SUPP...

Page 59: ...VERIFY THAT A L E R TLED REMAINS ON STEADY r 3 EDO 20 D U A L T H R U S T M O N I T O R 8 ADJUST POWER SUPPLY VOLTAGE PAST DANGER SETPOINT LEVEL AND VERIFY THAT DANGER LED GOES ON FLASHING IF FIRST OU...

Page 60: ...APL ui N fOR O f f D A N G E R A L E R T BYPZ 0 0 A B U T T E R E D WENDERS C 12 REDUCE AMPLITUDE TO BELOW ALARM SETPOINT LEVELS AND OBSERVE THATALERT AND D A N G E RLEDs GO OFF IF NONLATCHING P R E S...

Page 61: ...CT COM AND I I WIRING FROM CHANNEL A TERMINALS ON SIGNAL INPUT MODULE 2 CONNECT MULTIMETER AND POWER SUPPLY 3 SLIDE FRONT PANEL TO RIGHT AND ADJUST POWER SUPPLY FOR VOLTAGE OF 2 5 Vdc ON CHANNEL A TES...

Page 62: ...ULL SCALE VOLTAGE CHANGE WOULD RE 4 0 X 2 0 0 mV MIL 8 000 Vdc IF NORMAL DIRECTION iS TOWARD THE PROBE THE NOTED ZERO VOLTAGE MINUS FULL SCALE VOLTAGE IS 10 000 8 0 0 0 2 000 Vdc INPUT IF NORMAL IS AW...

Page 63: ...ON CABLE FROM P7 BE 3 RECONNECT EXTENSION CABLE TO AN IDENTICAL SUBSTITuTE RCBE N CALIBRATION INSTRUMENT 4 SET GAP VOLTAGE FOR APPROXIMATELY 9 Vdc 5 VERIFY THAT CHANNEL B OK LED IS ON PRESSRESET AND V...

Page 64: ...i G U I E R H E R S 1 7 1 id o 18 80 7 2 0 T R A N S D U C E R CHB A R R I E R S 1 7 7 1icc 7 2 0 0 R A N S Z U C E P 3RGEE V d c to 20 14 la T O TTR4PITERk m m R O P E V d c 10 18 53 ix S JERIF Y CH...

Page 65: ...M TERMINALS I R 3 ADJUST PROBE GAP FOR ZEROING VOLTAGE SPECIFIED BELOW FC P T R A N S D U C E R INSTALLPTi TRANSDUCER VOLTAGE 3300 7 700 WITHOUT EXTERNAL BARPIEPS WITH EXTERNAL BARRIERS 11 m m 14 m m...

Page 66: ...E R O V O L T A G E A D J U S T C O N T 3 ON E O N T C P IS L L z P A N E L TO RIGHT CONNECT mi__TNET7P TO CHANNEL A TEST E 0 11 PRPLA AND ADJUST CHANN FL A ZERO POTENTIOMETER FOR 2 5 0 0 Vdc MONITOR...

Page 67: ...N E D A B E N T V A L Y 7 2 0 0 SERIES PROXIMITOR MADE IN USA 18 TO 22 SOLID OR STRANDED 2 WIRE SHIELDED WITH 2 SHIELDS TERMINATED TO SIGNAL MODULE COMMON TO ELECTRICALLY ISOLATE AND PROTECT COAXIAL...

Page 68: ...M GROUND AND IS USED TO TERMINATE THE POTENTIAL EQUALIZATION BUS T O TA L EARTH LOOP IMPEDANCE MUST NOT EXCEED 1 OHM P R O X I M I T O R CASE MUST BE ELECTRICALLY ISOLATED FROM EARTH GROUND ELEC TRICA...

Page 69: ...RMINATED TO SIGNAL MODULE COMMON 1_ TO ELECTRICALLY ISOLATE AND PROTECT COAXIAL CONNECTIONS USE CON NECTOR PROTECTOR KIT PART NO 40113 02 4 TO MINIMIZE GROUND LOOP NOISE PROBLEMS A SINGLE E A R T H GR...

Page 70: ...179 01 3 3 R E C O M M E N D E D S P A R E P A R T S TO ORDER REPLACEMENT PARTS SPECIFY THE COMPLETE CATALOG NUMBER 3300 20 E n c a r r i c o c o AND THE REPLACEMENT PART NUMBER IF THE MONITOR HAS BEE...

Page 71: ...d per monitor full scale fre quencyrange and center scale marked for probe gap voltage at 1 6 resolution Green LEDs annunciate transducer OK condition red LEDs annunciate DANGER ALERT and BYPASS condi...

Page 72: ...ER RESPONSE THE METER RESPONSE TIME CAN BE SELECTED TO BE FAST OR SLOW WITH A FAST RESPONSE THE METER WILL FOLLOW THE THRUST POSITION EXACTLY AS SEEN B Y THE MONITOR IN INSTALLATIONS WHERE THERE IS A...

Page 73: ...H E E T 1 OF 1 SCHEMATIC DIAGRAM DUAL THRUST MONITOR 7 9 4 8 3 S H E E T S 7 OF 7 3300 SIGNAL NAMES S H E E T 1 OF 1 SCHEMATIC DIAGRAM DUAL RADIAL VIBRATION FRONT PANEL 78413 S H E E T 1 OF 1 ASSEMBL...

Page 74: ...Dual Thrust Monitor Maintenance 8 0 1 7 9 0 1 Blank Page 45...

Page 75: ...6 1 8 1 1 0 4 1 0 0 3 N M 0 5 t 3 0 0 0 0 0 0 0 0 0 I 0 0 0 0 4 0 0 3 1 0 0 0 1 _ 1 0 4 0 3 o f 0 0 0 9 0 3 2 0 0 0 0 0 OE a r t a 0 1 1 o a c o o l e t O E M 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 2...

Page 76: ...A I IS I t 0 9 S A 7 1 7 _2M TIA 6 8 3 4 8 22 AP2 A 2 p p L 4 5 68410 21 21 ggEFTA C H ASIGCOND a ACOrt 4 A 0 TP47 COO 001 TPI2 1527 33 AOKI 1 6 8 9 U0101 OW 040 6010 T O M O CKT5 3cLn cLna2 2 BIS C...

Page 77: ...1 6 3 ACM 0 0 W I 1113 1 0 1 SNT C f 0 I N I I 2 I N I J 1 4 X SNT SIDE a4NA R177 1 6 0 1912 I O N J I I S A SNT 6 0E1 w r 2W t 1 1 101 1 44 x6 v a n v 86 V S X7 v E 7 C 7 6 RP3 1 0 0 10W 1 S V 14 RP2...

Page 78: ...46190 07 0 812C 262 m a A4 14120 Re N S F I R 9 7 ass 4279 119 2374 119 0 9 5 818 ACOn 0 0ueC 56c45 A 4 3 3 3728 6 U 7 R93 ITT F SOT 5 1B I T 9 9 8 9 p 094 5 2 3 9 ACM V A 0 0 a R99 1524 179 o 478 R2...

Page 79: ...D 9 9 A X A l 1 S C S o l 5 0 5 S v 1 0 3 3 e c n 1150 0 0 0 5 1 1 1 A I I 0 D C 3 1 0 0 C 4 1 1 1 4 SLIT 5 0 0 I F 0 4 1 1 7 9 0 IA F 3 I N I I X 0 0 0 1 411 9 4 0 9 4 1 5 e 5 2 1 1 1 0 0 01 4 I D F...

Page 80: ...D SAT 4 8 A 551 4 8 A 551 1 1 A 5141 1 1 A 5141 4 1 A SAT 4 8 8 226 M O O T 9 5 1 2 22C i s P U I I SHT 2 8 8 23A NC 23C N C 248 B R O W S H T 4 1 8 24C MDR 9 4 7 4 1 9 ZSA N C 25C N C 26C 26A 27A 1...

Page 81: ...BLED IS 1 1 STIR SIGNAL NAME DENOTES NCTINE LOU IA D E L V E D RECORDER OUTPUTS THRUST DIRECTION LANCER VOTING SHIPPED AS I A TO ASS NA NORMAL IONARDS OR RELAY DRIVE 12 FREW PANEL 0 1 6 078413 13 BACK...

Page 82: ...t r y SAT I MOCK C r i t i c a l Posh SHT 1 3 7 6 ZOCR CAPS Cir CAPS Chan A Signal I n ch A DC Leve Out OR A INPUT C h a n Qt a t Bypass Ch A Bypass Ch 13 O M11 Gum INPUT ON Out Ch B DC Leve Chan B O...

Page 83: ...c h Danger R e l y D r i v e Danger A r r Danger F i r s t O u t I n p u t A l e r t F i r s t Out D r i v e Banger F i r s t O u t D r i v e F i r s t O u t Option Transducer Cap S i g n a l Channal...

Page 84: ...EL A BYPASS TTLAA TTL ALERT DRIVE CHANNEL A CH B BYPASS OR CHB BYP CHANNEL B BYPASS TTLAB TTL ALERT DRIVE CHANNEL B CHASSIS CHASSIS COMMON 1TLDA TTL DANGER DRIVE CHANNEL A COMMONA TRANSDUCER COMMON CH...

Page 85: ...ED l ESOC673L DNC RED LED 3 ESBR5731 ALERT RED LEDS LED 7 ESPES731 BYPASS RED 12 ESPY CC GREE BF L E D 7 S73I DNG RED LED 4 ESEIR57 ALERT RED LEDS NC LCD SEG 19A LCD SEC IBA LCD SEG 174 LCD SEG 329 LC...

Page 86: ...0 0 0 0 0 E Ad 1 1 8 0 0 0 o 0 1 8 0 6 1 8 0 2 1 3 0000 Do o o 0 O 0 O o o 0 o C D C D 8 1 l o 011_100 0 1 i 9eln 0 0 2 8 n O 1 8 6 D 1 0 m 1 0 0 0 0 0 0 0 0 0 n ban l 9 6 9 8 0 C L L L L L E C C D 0...

Page 87: ...SCHEMATIC D I A G R A M SIRM E P D X Y 7 8 4 6 3 SHEET 1 O F 2...

Page 88: ...INMAissueswsssysmslisms m 9 9 2 9 a m m i T l e T 4 M M M O g g e 9 9 9 9 9 U m s m m i t m m v 9 M R 1 9 M 1 1 9 t 9 1 m 9 I M I 9 1 99 9 9 9 9 9 9 0 4 0 0 111111 45 C9 6 SCHEMATIC D I A G R A M 7 8...

Page 89: ...f SCHEMATIC D I A G R A M QUAD R E L AY 8 3 7 3 0 SHEET 1 O F 2...

Page 90: ...I M M O M M P I R N F g a g g R K 2 1g1L ZzIRI EZEIEEMM1XMMIZRZgRM 1 MRM11 Mv7 121MTMvn15117 1VW41eM X 22 Y Y 2 Y e r ec9 o 0 t9 LC JC iiigY HANK 95 121 J V r 1 1 c9 v c9 CD C9 I SCHEMATIC DIAGRAM 8...

Page 91: ...ass Switch Option 2 2 Danger Mode Option 2 1 Danger Voting Option 2 1 Disassembly Procedure 1 5 Dual Thrust Monitor Option 1 E Expander Board Installation Removal 2 5 F Field Wiring Diagrams 3 8 First...

Page 92: ...tor Full Scale 2 4 Monitor OK Limits 2 1 Monitor Options 3 Recorder Out 2 2 P Programmable Options 3 Read Alert Setpoint Levels 1 1 Read Danger Setpoint Levels 1 1 Read Channel Thrust Position 9 Read...

Page 93: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: