Gas valve head pressure setting high fire  Propane G31: 

 
When setting the gas pressure for propane high fire 
(second stage ) contact SF should be closed  the high 
fire   pressure adjusting screw on the gas valve must be 
excluded. 
Connect a manometer on test point PV  

Remove the plastic cover from the adjuster 

RP1 RP2 

With a screw driver

 

hold the adjuster RP1 stationary 

and using a spanner, screw adjuster RP2 clockwise to 
the bottom of the thread until the correct pressure 
according to the data plate is achieved  . 

 
 
 

Gas valve  head pressure setting low fire Propane G31 : 

 
When setting the gas pressure for propane low fire  
(first stage) contact SF should be  open. The low fire 
pressure should be adjusted to the settings shown on 
the data plate and the data in the manual provided by 
adjusting screw RP1  
Clockwise increases the pressure  

Anti clockwise to decrease the pressure  
On completion replace the plastic cover and seal with 
paint   
Remove manometer ensuring that the test point screw 
is gas tight   

 

Gas valve gas SIT 843

 

 

 

 

 
 
 

On heaters with  2 gas valves the pressure regulation must be carried out on both gas valves 

 

 

Summary of Contents for RS/UHA2 105

Page 1: ...ed unit heaters 2 stage TECHNICAL INFORMATION ASSEMBLY INSTRUCTIONS USE AND MAINTENANCE RS UHA 2 BENSON HEATING LUDLOW ROAD KNIGHTON POWYS LD7 1LP MAY 2003 Benson Heating is a divison of Benson Climat...

Page 2: ...uctions for the safe installation use and maintenance of the appliance s Where proprietary items are incorporated into Benson Heating products detailed information and instructions are also provided a...

Page 3: ...R THE USER Operation Servicing Heater indication lights Receipt of product Transport Dimension FOR THE INSTALLER Location Wall bracket dimensions Gas connection Flue and combustion options Electrical...

Page 4: ...cond stage gas valve 2 C Fan capacitor FAN 1 Axial fan 1 FAN 2 Axial fan 2 type 5 F1 F2 Line fuse 6 3 A LF Green working light LL High temperature indication light LB Lockout indication RST Lockout re...

Page 5: ...II Second stage gas valve 2 C Fan capacitor FAN 1 Axial fan 1 FAN 2 Axial fan 2 FAN 3 Axial fan 3 Type 7 F1 F2 Line fuse LF Green working light LL High temperature indication light LB Lockout indicat...

Page 6: ...indicating gas type 6 Ensure settings are correct as per the manual and data plate CHANGE INJECTORS To change injectors Unscrew the natural gas injectors and replace them with the correct size inject...

Page 7: ...en the gas isolating cock switch on the electrical supply set the room thermostat to the desired temperature The heater is now ready for operation GAS VALVE Model SIT 843 two stage The heater must onl...

Page 8: ...ponents are correct for the installation including storage tank pipes and pressure valves etc Ensure that the pressure regulators are sealed after carrying out the conversion GAS PRESSURE REGULATION T...

Page 9: ...orrect pressure according to the data plate is achieved Gas valve head pressure setting low fire Propane G31 When setting the gas pressure for propane low fire first stage contact SF should be open Th...

Page 10: ...orking Check flue pipe and combustion air pipe are clear Faulty differential pressure switch Replace differential pressure switch Poor connection at pressure switch Check air pipe to switch is connect...

Page 11: ...bar Faulty burner tube Replace the burner tube Faulty ignition transformer Replace ignition transformer Faulty ignition Check the gas type is suitable for the heater Check the inlet gas pressure Check...

Page 12: ...correct and the air flow over the chamber is sufficient Faulty SND thermostat or control panel Replace SND thermostat or control panel Burner goes out due to the intervention of the TR thermostat and...

Page 13: ...and the air flow over the chamber is sufficient Faulty thermostat Replace thermostat Faulty fan Check fan capacitor Check fan motor Intervention of thermal overload on fan Check electrical absorption...

Page 14: ...heater Check the gas pressure Check burner head pressure The fan does not work Defective fan control Change fan control or SND thermostat Faulty fan Check fan capacitor Check the fan motor The heater...

Page 15: ...B22 Single flue option with condensate tee and roof terminal combustion air from inside the room Type 1 2 3 4...

Page 16: ...1000 with seal T Terminal with guard 100 U Condensate Tee with drain point V Pipe M M 100 L 200 without seal NOTE IMPORTANT MODEL 1 2 3 4 FLUE SPIGOT 100 female COMBUSTION AIR SPIGOT 100 female INSTA...

Page 17: ...165 ITEM DESCRIPTION A Pipe M F 100 L 1000 with seal T Terminal with guard 100 U Condensate tee with drain point Z Pipe M F 100 L 250 with seal NOTE IMPORTANT MODEL 5 6 7 FLUE SPIGOT SIZE 100 male COM...

Page 18: ...RIPTION A Flue pipe M F 100 L 1000 with seal H Bend 90 M F 100 with seal L Vertical co axial roof terminal kit 100 100 U Condensate tee with drain point V pipe M M 100 L 200 without seal NOTE IMPORTAN...

Page 19: ...with seal N Vertical co axial roof terminal kit 100 150 P Adaptor F F 150 L 200 with seal Q Bend 45 M F 150 with seal R Pipe M F 150 L 140 with seal S Bend 90 F F 100 with seal U Condensate tee with d...

Reviews: