#3 Switching element and Isolation power transformer
When the Q601 turns on, energy is stored in the transformer. During Q601 turn-off period, the
stored energy is delivered to the secondary of transformer. R607, C607 and D601 is a snubber
circuit. R615 is current sense resistor to control output power. (See Fig.4)
Fig. 4
#4 Rectifier and filter
D701 and C703 are to produce DC output. L701 and C704 are to suppress high Frequency switching
spikes. (See Fig.5)