Cable protection

able protection

able protection

able protection    

Secure the cables to the mounting system using UV-resistant cable ties. Protect exposed 

cables from damage using suitable precautions. Avoid direct and extended exposure to 

sunlight. 

    

Wiring and Installation Guidelines

Wiring and Installation Guidelines

Wiring and Installation Guidelines

Wiring and Installation Guidelines    
Please note the following instructions: 

 

To ensure the correct orientation of the module, the module should face southwards 

in the northern hemisphere and northwards in the southern hemisphere. 

 

The  module  must  be  installed  so  that  air  can  freely  circulate  around  it.  The  cells’ 

working  temperature  will  thus  be  reduced  and,  consequently,  the  module’s 

performance will be enhanced. 

 

Do not install modules in systemic and ongoing shade; this can cause the temperature 

of exposed cells to rise, reducing output, and may stress conductive bonds in module. 

 

The cross section for the conductors must be ensured that the voltage drop during 

the installation does not exceed 2% of its nominal voltage. 

 

BenQ Solar PV modules are supplied with or without cables, according to where they 

are ordered. Should they be supplied without cables, it is recommended that cables 

with cross sections between 4 and 10 mm2 be used.   

 

The  cables,  which  allow  easy  handling  while  providing  high  protection  against 

overloads  and  short-circuits,  are  formed  by  flexible  Cu  conductors,  cross  linked 

insulated  polyethylene  and  coated  with  polyvinyl  chloride  or  similar  insulation.  The 

insulation  should  be  flame,  acid  and  alkali  resistant  and  should  be  stored  in  an  area 

free of any corrosive gases. 

Wiring and Installation 

Wiring and Installation 

Wiring and Installation 

Wiring and Installation Warnings

Warnings

Warnings

Warnings    

 

The modules should be installed and handled by qualified persons only. 

 

Do not climb up or walk on the module.   

 

Do not drop the module or throw objects on the module. 

 

Use the module only for the purpose to which it is designed.   

 

Do not dismantle the module or remove any part, label, or piece assembled by the 

manufacturer without the manufacturer’s authorization.   

 

Do not concentrate sunlight or other artificial light sources onto the module. 

 

Use tools duly coated with insulating material while working with the modules. 

 

Always work under dry conditions. 

 

Do  not  install  the  modules  where  there  may  be  flammable  gases  or  vapors,  since 

sparks may be produced. 

 

Take care to avoid electric discharges when installing, wiring, starting up or carrying 

Summary of Contents for PM096B00

Page 1: ...In ns st ta al ll la at ti io on n G Gu ui id de e I IE EC C E ET TL L PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 Version 1 Version 1 Version 1 Version 1 1 1 1 1 Note The content...

Page 2: ...lar Module Specifications 5 2 1 PM200M00 Series 5 2 2 PM245P00 Series 5 2 3 PM250M01 Series 6 2 4 PM300P00 Series 6 2 5 PM318B00 PM318B01 PM096B00 Series 6 2 6 Performance of PV Modules 7 Chapter 3 Mo...

Page 3: ...b AND observe industry b AND observe industry best est est est p p p practices ractices ractices ractices may may may may result in result in result in result in dangerous conditions and could dangero...

Page 4: ...affect module performance Do not stand on drop scratch or allow objects to hit modules especially module glass Do not install or handle the modules when wet or during periods of high wind Do not insta...

Page 5: ...module Do not attempt to change or repair any part of the module Damaged modules broken glass torn back sheet broken j boxes broken connectors etc can present electrical hazards as well as laceration...

Page 6: ...x 38 70 x 1 57 in Module Weight Module Weight Module Weight Module Weight 15 4 kg 33 5 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM200M00_190 190 30 2 8 60 23 6 8 06 PM200M00_195 195 30 3 8 68 23...

Page 7: ...983 x 50 mm 77 01 x 38 70 x 1 96 in Module Weight Module Weight Module Weight Module Weight 28 kg 61 73 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM300P00_290 290 44 9 8 69 35 6 8 15 PM300P00_295...

Page 8: ...determining component voltage ratings conductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses and conduct...

Page 9: ...x wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty 3 1 Mounting with Screws Secu...

Page 10: ...of the mounting clamp to the edge of the module frame Clips and clamps are not provided by BenQ Solar There are two clamping methods available see below for specific measurements o Clamp on the long s...

Page 11: ...D4 D4 D4 D4 298 298 298 298 mm mm mm mm 11 73 in 11 73 in 11 73 in 11 73 in from the closest long side of the module PM PM PM PM3 3 3 300 00 00 00P P P P00 00 00 00 Module Clamp Location Details Modu...

Page 12: ...ble Pay attention to the following when wiring 1 1 1 1 Correct wiring scheme Correct wiring scheme Correct wiring scheme Correct wiring scheme Check that the wiring is correct before commissioning the...

Page 13: ...to where they are ordered Should they be supplied without cables it is recommended that cables with cross sections between 4 and 10 mm2 be used The cables which allow easy handling while providing hig...

Page 14: ...izing from the surface of the grounding holes or scratch off the anodizing before the grounding connection is made since the frame is fully insulated by anodizing An anti oxidation compound should be...

Page 15: ...lamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of each module bolt s...

Page 16: ...xes can be used to enable greater cable cross section area for long distance transmission The modules are qualified for the application class A Hazardous voltage IEC 61730 higher than 50V EN 61730 hig...

Page 17: ...ppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clean...

Page 18: ...es include an anodic oxide coating to increase produce life The cleaning cycle for regular anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coati...

Page 19: ...f the connection cable junctions Check the junction box sealing Should sealing faults be observed the items which have been affected should be replaced and cleaned Contact BenQ Solar for additional in...

Page 20: ...product meets or exceeds the requirements set forth by UL1703 for PV Modules This UL1703 Standard covers flat plate PV modules intended for installation on buildings and those intended to be freestan...