36
5. TV Color Alignment Procedure
5.1 TV Color Temp Alignment
Equipment:
-
Pattern generator (VG-828)
-
Lux meter ( CL-100)
OSD Default value used for YCBCR color temp alignment
Item
Value
Item
Value
USER>Picture>
Brightness 30
Contrast
17
Color 30
Tint 15
Factory>
SD
Sharpness 0
Brightness 180
Filter 3
Contrast 92
Color Temp
2
Saturation
90
User>Setup>White
Gamma Red, Green,
66
Gamma Red, Green,
0
1. Connect the signal to YCBCR component connector, and change Timing and pattern of
pattern generator :
Timing : NTSC(H:15.73 KHz,V:29.96 Hz)
pattern : 80% Gray
2. Color temperature spec:
Color temp. 4 is the same as that of 6500K
3. The variance of color coordinate via R,G,B gains:
4. Adjust 5400K / 6500K / 7500K temperature color.
5. Open Factory OSD and set the factory default value :
User>
setup
>white C0
C1(5700k C2(6500k C3(9300k
Gamma-Rgain 512 512 512 512
Gamma-Ggain 512 416 467 490
Gamma-Bgain 512 408 460 508