This section covers the Simply Secure Payment (SSP) module mechanical and electronic parts. 

TO PLACE AN ORDER FO R PARTS 

To place an order for parts please contact us by mail, email, phone, fax, or web using the information provided below. 

Note: 

Verbal orders cannot be accepted. A signed purchase order must be faxed or emailed to the Bennett Order Entry Department 
at 231-799-6202 or 

[email protected]

Bennett Pump Company 
Marketing Services 
1218 East Pontaluna Road 
Spring Lake, MI  49456 

Telephone from USA 1-800-235-7618 
Telephone from outside USA 231-798-1310, Extension 287, or 269 
Customer Service Telephone 231-719-6050, Facsimile 231-799-6202 
Email: 

[email protected]

 or 

 [email protected]

 

Website: 

www.bennettpump.com

 

For new manuals, visit our web page at 

www.bennettpump.com. 

ALL ORDERS MUST INCL UDE THE FOLLOWING INFORMATION:  

Note: 

Many electronic circuit boards have a factory-rebuilt equivalent. All rebuilt boards have a part number prefix of “RB”. 
Please refer to the 

Distributor Policy Manual

 for program terms and details. 

 

The part number, description, and quantity required. 

 

Provide a complete model and serial number, including the date code when ordering parts. The serial tag can be found 
inside the upper cabinet on side 1 of the Site Master.  

 

Your company’s name and address (if different from the shipping destination) for billing purposes. 

 

The complete “ship to” address. 

 

A purchase order number for order identification. 

SERIAL NUMBER IDENTIFICATION 

The serial number consists of a number 1 to 12 to designate month of manufacture followed by a letter to designate year. For 
example, K = 2008, L = 2009, M = 2010, N = 2011, P = 2012, and so on with a sequential number to follow.  

Note: 

Letters I, O, and Q are not used.

  

 

 

Figure 4.1 - Serial and Model Number Example

 

Summary of Contents for SITE MASTER EMV

Page 1: ...mation Installation Operation Maintenance Parts Schematics Only Trained Personnel May Work on This Equipment READ THIS MANUAL This manual has important information for safe installation and operation...

Page 2: ...799 6202 Email sales bennettpump com or salesintl bennettpump com Website www bennettpump com For new manuals visit our web page at www bennettpump com IMPORTANT Examine the shipment immediately upon...

Page 3: ......

Page 4: ......

Page 5: ...al Installation Requirements 7 Site Master SP Footprint 8 Wiring Instructions 9 Determining the Number of Wires Required 9 Point of Sale POS Communication 9 Beginning the Wiring Process 10 Installing...

Page 6: ...Bennett Site Master Instruction Manual Table of Contents ii Page Intentionally Left Blank...

Page 7: ...terminal or submerged pump before working on it Maintenance repairs must be done by authorized personnel only Warranty work may only be performed by Bennett certified technicians To prevent electric s...

Page 8: ...ional Fire Code 2018 Edition UNAUTHORIZED ALTERATION OF BENNETT PRODUCTS DANGER BEFORE PERFORMING ANY TYPE OF SERVICE TO THE DISPENSERS BE SURE TO SHUT OFF ALL ELECTRICAL SUPPLIES AND SECURE THEM IN T...

Page 9: ...DIMENSIONS Refer to Footprint Diagram 125927 P4208 located inside the Site Master or on the USB provided Site Master Series Maximum 19 25 32 width x 12 depth x 42 height Site Master Series Estimated S...

Page 10: ...erminal strip and converts the 120VAC into the 12VDC and 24VDC needed for the module to operate The payment module receives power from the Power Supply through the J5 connector on the SBC2 CPU Board a...

Page 11: ...the unit for conduit connections for the Site Master 2 Anchor the Site Master to the island with four bolts anchor bolts through the base frame Note When anchoring the Site Master always level the uni...

Page 12: ...A Installation must be in accordance with national electric code NFPA 70 The Automotive and Marine Service Code NFPA 30A and all state and local codes B Use only Underwriters Listed Threaded Rigid Co...

Page 13: ...Violet RS 485 positive 1 x 18ga Common 1 x 18ga Yellow RS 485 negative RS 485 wires should be twisted together no less than 3 turns per foot to reduce the effects of electrical noise on the communicat...

Page 14: ...ce panel ground bar Note Use 15 Amp neutral breaking circuit breakers which are supplied by the customer 6 Connect AC Power a Connect the neutral white 14 gauge wire to position 2 of the terminal stri...

Page 15: ...tallation 3 Pull a Green 12 ga stranded THHN ground wire through the junction box and wiring through and secure at grounding post near the terminal strip in the Site Master s electrical enclosure Term...

Page 16: ...ATION WIRING DIAGRAM 1 All wiring must be installed and used in accordance with the national electrical code NFPA 70 Automotive and marine service code NFPA 30A state and local electrical codes 2 All...

Page 17: ...for the other lock 5 To unlock either door turn the key counterclockwise until it stops POWER SWITCH WARNING To prevent electric shock make sure the current is off at the circuit breaker s and the br...

Page 18: ...on or off When power is applied to the Site Master the Bennett Logo will appear for approximately 3 seconds as shown in Figure 2 3 Note PLEASE PAY INSIDE will be displayed as shown in Figure 2 4 only...

Page 19: ...tem DC voltages then are sent over to the SBC2 Board through a multi pin conductor from connector J1 of the Power Board to connector J2 on the SBC2 Board The standard glass body fuses are located on a...

Page 20: ...n of the connections to the terminal strips of all the connections used on the power supply board as shown in Figure 3 3 J1 AC Input A 5 position header is used to receive incoming AC power J2 12 VDC...

Page 21: ...llow the suggested maintenance frequency and record results in the maintenance log Keep in a readily accessible location CLEANING PAINTED SURFACES 1 Wash the dispenser in a solution of warm water and...

Page 22: ...Bennett Site Master Instruction Manual Maintenance 18 Page Intentionally Left Blank...

Page 23: ...visit our web page at www bennettpump com ALL ORDERS MUST INCLUDE THE FOLLOWING INFORMATION Note Many electronic circuit boards have a factory rebuilt equivalent All rebuilt boards have a part number...

Page 24: ...cuit Board Asm Soft Key 2 7 126972 Display 1 8 132001 Bracket Display CPU Mount 2 9 132008 Bracket Mount SBC 1 10 129313 Circuit Board Assembly SBC2 1 11 113724 Card Reader MAGTEK 1 12 VARIOUS Bracket...

Page 25: ...a stranded THHN ground wire through the junction box and wiring through and secure at grounding post near the terminal strip in the Site Master s electrical enclosure Terminate the other end at the ma...

Page 26: ...DIAGRAM 1 All wiring must be installed and used in accordance with the national electrical code NFPA 70 Automotive and marine service code NFPA 30A state and local electrical codes 2 All wiring gauge...

Page 27: ...Bennett Site Master Instruction Manual Schematics 23 FOOTPRINT...

Page 28: ...Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Reviews: