34
123919 Rev C 5-17-18
di6its
0
Figure 14.4
COdE
14
How to Program the Dispenser for Operation
To select different options in Menu Code 14, follow this
procedure:
1. After the Manager’s Mode has been accessed, press
the number 1 and 4, then the
MODE
button on the
keypad. The price display indicates the dispenser is in
Menu Code 14.
If the dispenser has not been programmed since it
came from the factory, the display appears as in Figure
14.1. This is the default setting for the Flash option.
Press
ENTER
to see the Dash option. See Figure
14.2. This is the default setting for the Dash option.
Press
ENTER
to see the FLIP option. See Figure 14.3.
This is the default setting for the FLIP option. Press
ENTER
to see the Digit option. See Figure 14.4.
This is the default setting for the digit option.
2. To change a setting, use the 0 and 1 buttons on the
keypad to enter a new setting.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
3. When the correct option numbers appear in the main
display, press the
ENTER
button to save the selections
and then press the
CANCEL
button to exit this menu
code.