26
123919 Rev C 5-17-18
5. Once the
ENTER
button has been pressed, the target
pressure appears in the main display. The default
setting is 1 (see figure 7.3).
NOTE: The Target Pressure is only used for CNG
Type Dispensers.
NOTE: If the Dispenser Type is set for LNG then the
Target Pressure will not be available.
To change the setting press either the 1 or 2 button on
the keypad. Press the
ENTER
button to save the
setting.
When the correct option number appears in the main
display, press the
ENTER
button to save the selection
and figure 7.4 will appear.
6. At this point enter either 1 or 2 for the number of tiers
that will be used.
When the correct option number appears in the main
display, press the
ENTER
button to save the selection
and the screen will appear as it does in figure 7.5.
7. To change methane detector options press 0,1,2, or 3
on the keypad.
When the correct option number appears in the main
display, press the
ENTER
button to save the selection.
NOTE: To review or change the settings in Menu
Code 7, press the ENTER button on the keypad.
Each time the ENTER button is pressed the display
moves through the settings in Menu Code 7.
8. Press the
CANCEL
button to exit this menu code.
How to Program the Dispenser for Operation
tIEr
2
Figure 7.4
COdE
7
PRESS 1
P36
Figure 7.3
COdE
7
DETECT NONE
0
Figure 7.5
COdE
7