12
13
MENU
FUNCTION
Settable values
ON-OFF-(Default)
MEMO
LOGIC
TCA
The automatic closure is enabled or disabled.
Off: disabled automatic closure.
On: enabled automatic closure.
(ON)
IbL
The multi-at function is enabled or disabled.
Off: disabled multi-at function.
On: enabled multi-at function. The P.P. (Step-by-step) impulse or the
impulse of the transmitter has no effect in the opening phase.
(OFF)
SCL
The rapid closure is enabled or disabled.
On: enabled rapid closure. With open gate or gate in the opening phase,
the activation of the photocell causes the automatic closure of the gate 3
sec after its activation. This function is enabled only with TCA:ON
Off: rapid closure disabled.
(OFF)
PP
The operating mode The operating mode of the “P.P.” (Step-by Step)
button and of the transmitter is selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
(OFF)
PRE
Forewarning ashing light enabled or disabled.
Off: disabled forewarning ashing light.
On: enabled forewarning ashing light. The ashing light is activated 3
sec before the motor starts.
(OFF)
CLOC
The OPEN input mode is selected.
Off: OPEN input, with OPEN function.
On: OPEN input, with CLOCK function.
To be used for connection to timer for timed opening/closing. (CLOSED
contact: open gate. OPEN contact: normal operation).
(OFF)
htr
The Service Man function is enabled or disabled.
Off: Automatic operation.
On: Service Man operation.
The OPEN/CLOSE push-buttons should be kept pressed for the entire
operating time.
(OFF)
saut
The Service Man in closing phase function is enabled or disabled.
Off: Automatic operation.
On: Service Man in closing phaseoperation.
The CLOSE push-button should be kept pressed for the entire operating
time.
(OFF)
BLC
The lock function is enabled or disabled.
Off: Lock function disabled.
On: Lock function enabled. After the triggering of the closure limit switch-
es, the control unit delays the stop by approx. 0.5sec in order to allow a
better resting of the gate leaf onto the stoppers.
Note: In case of sliding gates, leave to OFF.
(OFF)
Pho1
Photocell 1 input in the opening phase is enabled or disabled.
On: Photocell 1 is activated in the closing phase only.
Off: Photocell 1 is activated in both opening and closing phases.
(OFF)
Pho2
Photocell 2 input in the opening phase is enabled or disabled.
On: Photocell 2 is activated in the closing phase only.
Off: Photocell 2 is activated in both opening and closing phases.
(OFF)
Pho3
Photocell 3 input in the opening phase is enabled or disabled.
On: Photocell 3 is activated in the closing phase only.
Off: Photocell 3 is activated in both opening and closing phases.
(OFF)
Pho4
Photocell 4 input in the opening phase is enabled or disabled.
On: Photocell 4 is activated in the closing phase only.
Off: Photocell 4 is activated in both opening and closing phases.
(OFF)
TSTP
The operating mode of output SCA/TESTPHOT is selected.
On: Photocell power supply in Test mode as per diagram at page 4.
Before each operation all PHOT inputs are checked. If the result is
negative, the operation will not take place.
Off: Output preset as open gate warning LED.
(OFF)
Faut
The check function of single failure is enabled or disabled.
Off: Single failure check is disabled.
On: Single failure check enabled in compliance with the Machinery Direc-
tive 98/37/CE.
(OFF)