11

selected torque value.
Once the desired torque is selected, move DIP 1 to OFF to memorise this presetting.

Note: with actuators for rolling shutters, preset torque at the maximum value.

RADIO SELF-LEARNING (DIP1:OFF/DIP6:ON)

The CELL.P control unit is equipped with a built-in radio module for the fixed or roll-on code of 
remote controls, with 433.92MHz frequency.
To use a remote control, it is first necessary to store its code in memory. The memorisation 
procedure is described hereunder. The device is able to store up to 64 different codes in 
memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per 
second, awaiting the key to the matched to the Step-by-Step/OPEN function (see DIP6);
When the key is stored in memory, exit from the programming mode;
By pressing P1 twice, the control unit enters the radio learning phase: DL1 red LED flashes 2 time 
per second, awaiting the key to the matched to the CLOSE function;
When the key to be matched is memorised, exit from the programming mode.
If the programming mode must be left without storing any remote control signal, press P1 key 
until DL1 red LED starts to flash in “power on” mode (see LED diagnostics on page 7).
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10 
seconds (during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-
buttons.
When the LEDs switch back again to the original configuration, the control unit has completed 
the memory reset.

NOTE: 

The transmitters are memorised on an EPROM memory (U2), which can be extracted from the 
control unit and inserted in a new CELL.P control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the opening/closing of the 
motor.

LED DIAGNOSTICS

The red LED indicates the activation of inputs according to the legend hereunder:
STOP  

 

on with fixed light 

DAS/PHOT

  

rapid flashing 

SWO 

 

1 flash with 2-second interval 

SWC 

 

2 flashes with 2-second interval

OPEN+CLOSE  

3 flashes with 2-second interval

By flashing slowly, the red LED also indicates that the unit is powered.
The green LED indicates the movement direction of the motor and the status of the gate according 
to the legend hereunder:
OPENING 

 

1 flash with 1-second interval

CLOSING  

 

2 flashes with 1-second interval

Open gate without TCA 

on with fixed light