11
selected torque value.
Once the desired torque is selected, move DIP 1 to OFF to memorise this presetting.
Note: with actuators for rolling shutters, preset torque at the maximum value.
RADIO SELF-LEARNING (DIP1:OFF/DIP6:ON)
The CELL.P control unit is equipped with a built-in radio module for the fixed or roll-on code of
remote controls, with 433.92MHz frequency.
To use a remote control, it is first necessary to store its code in memory. The memorisation
procedure is described hereunder. The device is able to store up to 64 different codes in
memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per
second, awaiting the key to the matched to the Step-by-Step/OPEN function (see DIP6);
When the key is stored in memory, exit from the programming mode;
By pressing P1 twice, the control unit enters the radio learning phase: DL1 red LED flashes 2 time
per second, awaiting the key to the matched to the CLOSE function;
When the key to be matched is memorised, exit from the programming mode.
If the programming mode must be left without storing any remote control signal, press P1 key
until DL1 red LED starts to flash in “power on” mode (see LED diagnostics on page 7).
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10
seconds (during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-
buttons.
When the LEDs switch back again to the original configuration, the control unit has completed
the memory reset.
NOTE:
The transmitters are memorised on an EPROM memory (U2), which can be extracted from the
control unit and inserted in a new CELL.P control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the opening/closing of the
motor.
LED DIAGNOSTICS
The red LED indicates the activation of inputs according to the legend hereunder:
STOP
on with fixed light
DAS/PHOT
rapid flashing
SWO
1 flash with 2-second interval
SWC
2 flashes with 2-second interval
OPEN+CLOSE
3 flashes with 2-second interval
By flashing slowly, the red LED also indicates that the unit is powered.
The green LED indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
OPENING
1 flash with 1-second interval
CLOSING
2 flashes with 1-second interval
Open gate without TCA
on with fixed light