BRAINY CONTROL UNIT 

INPUT/OUTPUT FUNCTIONS

N° Terminals

Function

Description

1-2-3

Power supply

Input 230Vac 50Hz (1-GND/2-Phase/3-Neutral)

4-5-6

Motor 1

Connection of motor 1: (4-start/5-Com/6-start) 

7-8-9

Motor 2

Connection of motor 2: (7-start/8-Com/9-start) 

10-11

Blinking light

Connection of blinking light 230Vac 40W max. 

12-13

TLS

N.O. clean contact for courtesy light, timer, etc. 
The activation time is regulated by the parameter TLS

14-15

24 Vac

Accessories power supply output 24Vac/1A max. 

16-17

Lock 12Vdc

Accessories power supply output 12Vac/10W for electric lock (16:0V, 17:+12V)

18-19

AUX1

Normally Open clean contact, configurable as SCA- open gate light (default) or photocell test.

20-21

EDGE

Input, sensitive edge contact 
Resistive edge: “DAS” Jumper closed
Mechanical edge: “DAS” Jumper open 
When the edge is activated, the gate movement is stopped and reversed for about 3s.

22

SWO-M1

OPEN limit switch input motor 1 (N.C contact.)

23

SWC-M1

CLOSE limit switch input motor 1 (N.C. contact)

24

SWO-M2

OPEN limit switch input motor 2 (N.C. contact)

25

SWC-M2

CLOSE limit switch input motor 2 (N.C. contact)

26-27

COM

Common for limit switch and all the control inputs. 

28

Step-by-Step

Step-by-Step button input (N.O. contact) 

29

PED

Pedestrian button input (N.O. contact) 

30

OPEN

OPEN button input (N.O. contact), configurable as Clock contact

31

CLOSE

CLOSE button input (N.O. contact)

32

PHOT

Active photocell input on opening and closing

33

PHOT CLOSE

Active photocell input only on closing

34

STOP

STOP button input (N.C. contact) 

35-36

Antenna

Antenna connection for plug-in radio receiver board (35-screen/36-signal).

37-38

AUX2

Voltage-free Normally Open Contact. Configurable as second radio channel (default) or SCA-
open gate LED.

J3

Radio

Plug-in connector for radio receiver.

NOTES

The EDGE must be connected exclusively to the special inputs 20/21. 

Two types of EDGE may be used:

 

If an edge with resistance 8K2 is used, close the Jumper “DAS”.

  If a mechanical edge with N.C. contact is used, open the Jumper “DAS”.
  If the edge is not used, bridge the terminals 20-21 and open the Jumper “DAS”.

TO CHECK CONNECTIONS:

1)  Cut-off power supply.
2)  Manually release the wings, move them to approx. half-stroke and lock them again.
3)  Reset power supply.
4)  Send a step-by-step control signal by pressing the button or the remote control key.
5)  The wings should start an opening movement. 
 

If this is not the case, invert the movement wires of the motor. (4<>6 for motor M1, and 7<>9 for motor M2) and the relevant limit 
switch inputs (22<>23 for motor M1, and 24<>25 for motor M2).

PROGRAMMING

The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the 
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software 
release.

TO ACCESS PROGRAMMING

1 – Press the button <PG>, the display goes to the first menu, Parameters “PAR”. 
2 – With the <+> or <-> button, select the menu you want.
3- Press the button <PG>, the display shows the first function available on the menu.

Summary of Contents for BRAINY

Page 1: ...L8542910 04 2011 rev 1 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI BRAINY ...

Page 2: ... M1 Close SWO M2 Open SWC M2 Close P P COM COM PED OPEN CLOSE PHOT PHOT Close STOP SHIELD ANT ANT SCA 24Vac 3W max 24Vac 1A max 19 18 17 16 15 14 Lock 12Vac 10W 19 18 17 16 15 14 31 32 33 31 29 28 27 31 32 33 31 29 28 27 24Vac 24Vac COM NCNO RX1 TX1 SCA PHOTO TEST 19 18 17 16 15 14 24Vac 24Vac COM NCNO RX2 TX2 J2 DAS Open DAS N C J2 DAS Close DAS 8K2 DAS _ _ _ _ Code Encoder M1 M1 s Encoder M2 M2 ...

Page 3: ...ŔSVCZ CMPLVKįDF CF XZDJįHBOJB JDI X TQPTØC VNPŤMJ XJBKįDZ PUXBSDJF OBLSZXLJ 1SFNFSF MF BMFUUF TVJ mBODIJ QFS THBO DJBSF MF EVF NBTDIFSF DPQSJWJUJ 3JNVPWFSF MF EVF WJUJ TVM MBUP EJ BQFSUV SB EFTJEFSBUP MMFOUBSF MF EVF WJUJ DPO GVO JPOF EJ DFSOJFSB TFO B SJNVPWFSMF JO NPEP EB DPOTFOUJSF M BQFSUVSB EFM DPQFSDIJP 1SFTT UIF UBCT PO UIF TJEFT UP SFMFBTF UIF UXP NBTLT UIBU DPWFS UIF TDSFXT 3FNPWF UIF UXP...

Page 4: ... of the ground according to the regulations in force The electrical installation and the operating logic must comply with the regulations in force The leads fed with different voltages must be physically separate or they must be suitably insulated with additional insulation of at least 1 mm The leads must be secured with an additional fixture near the terminals During installation maintenance and ...

Page 5: ... in radio receiver board 35 screen 36 signal 37 38 AUX2 Voltage free Normally Open Contact Configurable as second radio channel default or SCA open gate LED J3 Radio Plug in connector for radio receiver NOTES The EDGE must be connected exclusively to the special inputs 20 21 Two types of EDGE may be used If an edge with resistance 8K2 is used close the Jumper DAS If a mechanical edge with N C cont...

Page 6: ... the opening percentage over the total stroke memorised during self setting With ENC OFF the value is the opening percentage over the time preset in TM1 parameter 1 99 50 PMo1 The torque applied to motor 1 in the OPENING phase is adjusted 1 99 40 PMC1 The torque applied to motor 1 in the CLOSING phase is adjusted 1 99 40 PMo2 The torque applied to motor 2 in the OPENING phase is adjusted 1 99 40 P...

Page 7: ...ing disabled OFF Sld Enables or disables slowing On Slowing active Off Slowing excluded OFF PP Selects the operating mode of the Step by step button and of the transmitter On Operation OPEN CLOSE OPEN Off Operation OPEN STOP CLOSE STOP OFF PRE Enables or disables pre blinking On Pre blinking enabled Blinking is activated 3s before the motor starts Off Pre blinking disabled OFF HAM Enables or disab...

Page 8: ... lock normally fed at 12Vdc Before each opening manoeuvre the power supply is interrupted for the time set by the parameter TLOC Off Electric lock with latch normally not fed Before each opening manoeuvre power is fed at 12Vdc for the time set by the pa rameter TLOC OFF TRK The check for integrity of TRIAC is enabled or disabled On Activated check if TRAC is faulty the motor does not start Off the...

Page 9: ...gain repeat the operation RES RESET of the control unit ATTENTION Returns the control unit to the default values Pressing the PG button for the first time causes blinking of the letters RES pressing the PG button again resets the control unit NMAN Displays the number of complete cycles open close carried out by the automation When the PG button is pressed for the first time it displays the first 4...

Page 10: ...In this operating mode the NOT ON logics and the ENC OFF logics must be preset All parameters must be preset manually In particular values of TM1 TM2 must be some seconds higher than the actual operating time AUTOMATIC SYSTEM WITH ELECTROMECHANIC LIMIT SWITCHES AND CONNECTION TO ENCODER In this operating mode the NOT OFF logics and the ENC ON logics must be preset Start a self test operation as in...

Page 11: ...it switches on according to the following scheme PHOT O SWC M1 STOP SWO M1 SWO M2 SWC M2 PHOT C DAS P P PED OPEN CLOSE WASTE DISPOSAL If the product must be dismantled it must be disposed according to regulations in force regarding the differentiated waste disposal and the recycling of components metals plastics electric cables etc For this operation it is advisable to call your installer or a spe...

Page 12: ...AUTOMATISMI BENINCÀ SpA Via Capitello 45 36066 Sandrigo VI Tel 0444 751030 r a Fax 0444 759728 ...

Reviews: