BRAINY

Summary of Contents for BRAINY

Page 1: ...L8542910 04 2011 rev 1 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI BRAINY ...

Page 2: ... M1 Close SWO M2 Open SWC M2 Close P P COM COM PED OPEN CLOSE PHOT PHOT Close STOP SHIELD ANT ANT SCA 24Vac 3W max 24Vac 1A max 19 18 17 16 15 14 Lock 12Vac 10W 19 18 17 16 15 14 31 32 33 31 29 28 27 31 32 33 31 29 28 27 24Vac 24Vac COM NCNO RX1 TX1 SCA PHOTO TEST 19 18 17 16 15 14 24Vac 24Vac COM NCNO RX2 TX2 J2 DAS Open DAS N C J2 DAS Close DAS 8K2 DAS _ _ _ _ Code Encoder M1 M1 s Encoder M2 M2 ...

Page 3: ...ŔSVCZ CMPLVKįDF CF XZDJįHBOJB JDI X TQPTØC VNPŤMJ XJBKįDZ PUXBSDJF OBLSZXLJ 1SFNFSF MF BMFUUF TVJ mBODIJ QFS THBO DJBSF MF EVF NBTDIFSF DPQSJWJUJ 3JNVPWFSF MF EVF WJUJ TVM MBUP EJ BQFSUV SB EFTJEFSBUP MMFOUBSF MF EVF WJUJ DPO GVO JPOF EJ DFSOJFSB TFO B SJNVPWFSMF JO NPEP EB DPOTFOUJSF M BQFSUVSB EFM DPQFSDIJP 1SFTT UIF UBCT PO UIF TJEFT UP SFMFBTF UIF UXP NBTLT UIBU DPWFS UIF TDSFXT 3FNPWF UIF UXP...

Page 4: ... of the ground according to the regulations in force The electrical installation and the operating logic must comply with the regulations in force The leads fed with different voltages must be physically separate or they must be suitably insulated with additional insulation of at least 1 mm The leads must be secured with an additional fixture near the terminals During installation maintenance and ...

Page 5: ... in radio receiver board 35 screen 36 signal 37 38 AUX2 Voltage free Normally Open Contact Configurable as second radio channel default or SCA open gate LED J3 Radio Plug in connector for radio receiver NOTES The EDGE must be connected exclusively to the special inputs 20 21 Two types of EDGE may be used If an edge with resistance 8K2 is used close the Jumper DAS If a mechanical edge with N C cont...

Page 6: ... the opening percentage over the total stroke memorised during self setting With ENC OFF the value is the opening percentage over the time preset in TM1 parameter 1 99 50 PMo1 The torque applied to motor 1 in the OPENING phase is adjusted 1 99 40 PMC1 The torque applied to motor 1 in the CLOSING phase is adjusted 1 99 40 PMo2 The torque applied to motor 2 in the OPENING phase is adjusted 1 99 40 P...

Page 7: ...ing disabled OFF Sld Enables or disables slowing On Slowing active Off Slowing excluded OFF PP Selects the operating mode of the Step by step button and of the transmitter On Operation OPEN CLOSE OPEN Off Operation OPEN STOP CLOSE STOP OFF PRE Enables or disables pre blinking On Pre blinking enabled Blinking is activated 3s before the motor starts Off Pre blinking disabled OFF HAM Enables or disab...

Page 8: ... lock normally fed at 12Vdc Before each opening manoeuvre the power supply is interrupted for the time set by the parameter TLOC Off Electric lock with latch normally not fed Before each opening manoeuvre power is fed at 12Vdc for the time set by the pa rameter TLOC OFF TRK The check for integrity of TRIAC is enabled or disabled On Activated check if TRAC is faulty the motor does not start Off the...

Page 9: ...gain repeat the operation RES RESET of the control unit ATTENTION Returns the control unit to the default values Pressing the PG button for the first time causes blinking of the letters RES pressing the PG button again resets the control unit NMAN Displays the number of complete cycles open close carried out by the automation When the PG button is pressed for the first time it displays the first 4...

Page 10: ...In this operating mode the NOT ON logics and the ENC OFF logics must be preset All parameters must be preset manually In particular values of TM1 TM2 must be some seconds higher than the actual operating time AUTOMATIC SYSTEM WITH ELECTROMECHANIC LIMIT SWITCHES AND CONNECTION TO ENCODER In this operating mode the NOT OFF logics and the ENC ON logics must be preset Start a self test operation as in...

Page 11: ...it switches on according to the following scheme PHOT O SWC M1 STOP SWO M1 SWO M2 SWC M2 PHOT C DAS P P PED OPEN CLOSE WASTE DISPOSAL If the product must be dismantled it must be disposed according to regulations in force regarding the differentiated waste disposal and the recycling of components metals plastics electric cables etc For this operation it is advisable to call your installer or a spe...