19
Maintenance of peristaltic pumps
-
The pump hose has reached the end of its service life after 500/600 operating hours
(chemical compatibility) and must be replaced annually
-
The hoses of the drain and supply pipe must be replaced every two years.
-
The nozzles must be descaled and rinsed every two years. The limescale can block the
supply or return. We recommend the use of chlorine with anti-limescale agent
(ZWCX1232).
-
The drain and supply pipes must be replaced 2 times a year. .
-
A maintenance kit is available: ZWMX2201-Z
-
The pumps must always be higher than the supplied liquids.
-
Use the correct, prescribed products for the peristaltic pumps and the Santoprene
hose (to be replaced annually as indicated).
Warnings
○
Improper installation may cause an electrical or chemical hazard that could result in
serious injury
○
Never mix acid and liquid chlorine. These react to form dangerous chlorine gas
○
Keep the installation and chemicals out of the reach of children. Always wear protective
gloves and goggles when working on the installation.
○
NEVER make internal adjustments to the dosing unit.
○
If you are not familiar with the pool filter system and the dosing unit:
-
Try not to rent anything without consulting your supplier, a professional pool
contractor.
-
Read the entire installation and operating manual before using the dosing unit.