Benezan Electronics
Hard- and software development
Installation ManualBreakout Board
Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg
Phone: +49 (0)7457/946365 0 benezan-electronics.de
Page
Breakout8-Installation_Englisch
(Vereinigte Staaten).docx
docx 22.09.2020
Safety Instructions
The Breakout Board may only be installed and put into operation by qualified personnel.
Please read the operating instructions carefully and follow all instructions exactly. Improper
installation or operation of the device can cause damage to the electronics or the machine and
can result in dangers to the health of the operating personnel.
Depending on the hazard potential of the machine, additional safety measures may be
required, such as door interlocks and standstill monitoring. As a rule, such safety functions
must be implemented purely electromechanically with external circuits (not included in the
scope of delivery) and must not depend solely on software and PC hardware. The system manufacturer, who
assembles the breakout board and other components to form the overall system, and the system operator are
responsible for compliance with the legal regulations.
Connections
The connections of all terminals are numbered from left to right. The pins of the SUBD connector and the pins
for the jumpers are numbered from top to bottom.
Please note
: The contacts of the RJ45 sockets are numbered
from bottom (1) to top (8).
Power supply (5-pole terminal X1, top right)
No. Description
1
5V output (max. 0.5A)
2
Ground 0V
3
12V output (max. 0.5A)
4
Ground 0V
5
24V input (15 ... 75V, max. 1A)