background image

Benezan Electronics 

Hard- and software development 

Installation ManualBreakout Board 

 

 

Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg 

Phone: +49 (0)7457/946365 0 benezan-electronics.de 

Page

 

Breakout8-Installation_Englisch 

(Vereinigte Staaten).docx

docx 22.09.2020

 

 

Safety Instructions 

The  Breakout  Board  may  only  be  installed  and  put  into  operation  by  qualified  personnel. 
Please read the operating instructions carefully and  follow  all instructions exactly. Improper 
installation or operation of the device can cause damage to the electronics or the machine and 
can result in dangers to the health of the operating personnel.  

Depending  on  the  hazard  potential  of  the  machine,  additional  safety  measures  may  be 

required,  such  as  door  interlocks  and  standstill  monitoring.  As  a  rule,  such  safety  functions 
must  be  implemented  purely  electromechanically  with  external  circuits  (not  included  in  the 
scope  of  delivery)  and  must  not  depend  solely  on  software  and  PC  hardware.  The  system  manufacturer,  who 
assembles  the  breakout  board  and  other  components  to  form  the  overall  system,  and  the  system  operator  are 
responsible for compliance with the legal regulations. 

 

Connections 

The connections of all terminals are numbered from left to right. The pins of the SUBD connector and the pins 
for the jumpers are numbered from top to bottom. 

Please note

: The contacts of the RJ45 sockets are numbered 

from bottom (1) to top (8). 

 

Power supply (5-pole terminal X1, top right) 

No.  Description 

5V output (max. 0.5A) 

Ground 0V 

12V output (max. 0.5A) 

Ground 0V 

24V input (15 ... 75V, max. 1A) 

Summary of Contents for Mini Breakout Board

Page 1: ...fferent configurations Depending on the selected configuration additional functions such as control of a frequency converter or speed controller reference switches up to 2 relay outputs an output for...

Page 2: ...itional safety measures may be required such as door interlocks and standstill monitoring As a rule such safety functions must be implemented purely electromechanically with external circuits not incl...

Page 3: ...axis 21 9 step 4th axis 22 10 Reference switch Z 23 11 Emergency stop 24 12 Reference switch Y 25 13 Reference switch X Additional functions 6 pin terminal X2 top left No Description 1 Ground 0V for...

Page 4: ...tion_Englisch Vereinigte Staaten docxdocx 22 09 2020 Power stage outputs 4 x RJ45 center Attention Pin 1 is down pin 8 up No Description 1 Current reduction 2 Signal ground 3 Step 4 5V 5 Direction 6 5...

Page 5: ...sumers inductive proximity switches holding brake an extra power supply unit is necessary For fans external sensors or additional circuits the board provides regulated 5V and 12V outputs terminal X1 A...

Page 6: ...i e the corresponding LPT pin is high when the switch input is open low and low when the switch input is closed high Normally closed or normally open contacts can be used if the polarity is selected a...

Page 7: ...nds to a voltage of 0V 10 corresponds to 1V 20 corresponds to 2V etc up to 100 and 10V The frequency of the PWM signal PWM base frequency should be at least 45Hz so that the ripple of the analog signa...

Page 8: ...e a bridge from stripe no 4 to 5 means that relay 1 is switched with LPT pin 1 An erroneous multiple use of a signal source is thus automatically excluded1 No Description Reference 12 Sensor supply 24...

Page 9: ...s described above depending on the application The load capacity of the 5V output at X1 has been increased from 150mA to 0 5A so that the USB CNC board can be supplied from the breakout board and no e...

Page 10: ...8 Aeff Voltage at relay Holding brake 30 V Current at relay holding brake 5 Aeff Electrical connection values Parameters min max Unit Operating voltage nominal 24V 15 75 V Power consumption without ex...

Page 11: ...s than 3 power amplifiers are connected a dummy plug with a bridge between pin 7 and 8 must be inserted for the missing axes Is the emergency stop switch connected For test purposes only a jumper may...

Page 12: ...ifiers are connected or not all are supplied with voltage 4 LED E Stop red right lights up a The emergency stop switch X2 Pin 5 and 6 is not connected or pressed b The power supply is not sufficient o...