![Benezan Electronics Beamicon2Basic Installation Manual Download Page 14](http://html1.mh-extra.com/html/benezan-electronics/beamicon2basic/beamicon2basic_installation-manual_2732713014.webp)
Benezan Electronics Installation Guide for Beamicon2Basic
Hardware and software development and
the MDLCNC-T4V6 driver
Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg
Phone:
+49
(0)
7457/946365
0
benezan-
electronics.de
Page
14
Beamicon2Basic_Manual_Letmathe_Englisch
(Vereinigte Staaten).docx
02.10.2020
Relay
FU plug "CK"
+5V
FU plug "5V"
GND5V
FU plug "GND
“
+12V
Plug reference inputs "12V
“
GND12V
Plug reference inputs "0V
“
Hint:
By plugging in the "FU module" expansion module, the electrical isolation of the 5V and the
operating voltage of the output stage is removed. This is absolutely no problem and poses no risk, as
the galvanic isolation to the PC is provided by the micropod. By using the micropod, breakout boards
and power amplifiers do not need to have galvanic isolation.
Attention! The connections for the operating voltage "+5V" and "+12V" are
not protected against reverse polarity! Make sure that the connection is
correct.
Connect the output "0..10V" together with the connection "GND" according to the manual of
your frequency inverter.
The output is short-circuit proof and safe against accidental
application of a voltage up to max. 31V.
This will destroy the module.
The relay can be used to switch the input for spindle forward of your frequency converter.