Brief product description 

The interface board allows the operation of up to four stepper motor or servo output stages with the Beamicon2 CNC software.  A 
normal network connection with RJ45 cable is used for data transfer from the PC. No LPT port is required, and the well-known 
limitations  of  step  frequency  and  timing  problems  are  a  thing  of  the  past.  The  board  can  be  adjusted  to  many  different 
configurations. Depending on the selected configuration, additional functions  such as control of a  frequency converter or speed 
controller, reference switches, up to 2 relay outputs and an output for a holding brake are available. 

All signals are galvanically isolated from the PC, so that a maximum of noise immunity is achieved. All machine-side signals 

are  designed  for  24V  level,  ensuring  robustness  and  compatibility  with  industrial  sensors.  Ready-made  connection  cables  for 
BEAST  stepper  motor  power  amplifiers,  UHU-DC  servo  controllers  and  brushless  servo  systems  (BLAST,  SpeedCube  and 
Sanyo-Denki R-series) are available (not included), so that quick and error-free wiring is possible. 

Summary of Contents for Beamicon2 IoExt1

Page 1: ...ll known limitations of step frequency and timing problems are a thing of the past The board can be adjusted to many different configurations Depending on the selected configuration additional functio...

Page 2: ...afety measures may be required such as door interlocks and standstill monitoring As a rule such safety functions must be implemented purely electromechanically with external circuits not included in t...

Page 3: ...input Power supply 5 pole terminal X1 top right No Description 1 5V output max 150mA 2 Ground 0V 3 12V output max 0 3A 4 Ground 0V 5 24V input 15 75V Relay outputs 6 pole terminal X4 bottom right No D...

Page 4: ...re reliable operation however the following rules must be observed The breakout board must be connected either directly to the PC or to the first switch after the PC A further switch may only be added...

Page 5: ...and jumpers 10 11 must be plugged in see also Chapter 4 Configuration If the power stage is to remain active during an emergency stop recommended shorter braking distance jumpers 7 11 must remain open...

Page 6: ...against payment Relay outputs The relay outputs 1 and 2 can be used to switch 230V consumers such as spindle motor coolant pump or chip extractor The current consumption must not exceed 8A per relay o...

Page 7: ...ith old thyristor controllers whose speed input is partially connected to the mains voltage These must not be used If in doubt please refer to the data sheet of the frequency inverter or speed control...

Page 8: ...Breakout Board Installation Guide Nicolas Benezan Stauffenbergstr 26 72108 Rottenburg Phone 49 0 7457 946365 0 benezan electronics de Page Netbob1 installation docx22 09 2020 No Description Power Rea...

Page 9: ...d in detail in the Beamicon2 software manuals Therefore only the special features of the breakout board will be discussed here The easiest way to configure the software is to select the default parame...

Page 10: ...tep signals are disabled When using stepper motor output stages the current reduction signal must be applied to the enable pin if they have a current reduction input This is always active when all dri...

Page 11: ...ent at the relay outputs X4 8 Aeff Voltage at relay Holding brake 30 V Current at relay holding brake 5 Aeff Electrical connection values Parameters min max Unit Operating voltage nominal 24V 15 75 V...

Page 12: ...ifiers are used jumper JP4 4 5 must be plugged in If less than 3 power amplifiers are connected a dummy plug with a bridge between pin 7 and 8 must be inserted for the missing axes Is the emergency st...

Page 13: ...ule selected if several modules are in the network 4 LED Ready green right does not light up a ChargePump signal not assigned or module is not connected b Software not started or running in demo mode...