Attachment 1: Introduction of TF Series PC software
This PC software only supports the Windows operating system. It is suitable for any products of TF series,
but the output of those products is limited to the serial port communication protocol. Detailed operations
are as below.
Figure 7: Interface of TF Series software
1
Product Type/Serial Port Control Zone [SETTINGS]
Product Type: connect the LiDAR via TTL-USB board to the PC. As shown in the figure, select ‘TFmini-
S’.
Serial port (COM): select the right serial port number corresponding to the LiDAR. Baud rate is set to
115200 as default.
CONNECT/DISCONNECT: Click [CONNECT] button to establish the connection with LiDAR. Click
[DISCONNECT] button to terminate the connection.
2
Function Zone [FUNCTION]
Pix Mode: check the checkbox to enable Pix mode. Uncheck the checkbox will set TFmini-S to default
output format.
In Pix mode, the frame rate (Effective Points) calculated by test software is unreliable.
FREEZE/CLEAR: After clicking [FREEZE], time-line chart in zone [4] will stop updating. On clicking