Operating the unit

1) Open the battery door and insert a battery properly.
2) Pull the trigger to turn on the unit.
3) Aim at the target surface and pull the trigger, then 

temperature will be shown on the LCD. This unit is 
equipped with a laser which is only used for aiming.

Locating a Hot Spot

To find a hot spot, aim the thermometer outside of 
interest, then scan across with an up and down motion 
until you locate the hot spot. (Figure 3)

F. LCD display & Buttons

1. LCD display: 

a) Measurement reading
b) Measurement unit
c) Laser on icon
d) Backlight on icon
e) Battery power icon
f)

Scanning icon

g) Data hold icon
h) Mode emissivity indicator
i)

Data storage / read icon

j)

Low temperature icon

k) High temperature icon

1) Trigger: When turn on LCD display VERXX software 

version for 1 sec. And turn to display reading with 
scan icon. Release the trigger, Display HOLD icon. 
Built in auto power off in 30 sec.

2) Laser/Back light button: When back light turn on any 

operation will remain back light for 10 sec. LCD 
indicate on/off status.

3) - 6) Key function: Press 3key. LCD subdisplay blinks 

MAX-MIN-DIF-AVG-HAL-LAL-STO-EMS segment 
(Only main display means normal measuring mode) 
press 4key to enter

G. Maintenance

1. Lens Cleaning: 

Blow off loose particles using 

clean compressed air. Gently brush remaining 
debris away with a moist cotton swab. The 
swab may be moistened with water.

2. Case cleaning: 

Clean the case with a damp 

sponge/ cloth and mild soap.

Note:

1) 1) Do not use solvent to clean plastic lens.
2) 2) Do not submerge the unit in water.

H. Specification

Temperature range

-50 ~ 900  C (-58 ~ 1652  F)

Accuracy

0~900 C (32 ~1652 F)  
±1.5 C (± 2.7 F ) or ±1.5%

-50~0 C (-58~32 F) ±3 C ( ±5 F )
Whichever is greater

Resolution

0.1 C or 0.1 F

Repeatability

1% of reading or 1 C

Response time

500 mSec, 95% response

Spectral response

8-14 um

Emissivity

0.10~1.00 Adjustable (0.95Preset)

Distance to Spot size

12:1

Operating Temperature

0~ 40 C (32 ~ 104 F)

Operating Humidity

10~95%RH non-condensing up to 
30 C (86 F)

Storage Temperature

-20 ~ 60 C (-4 ~ 140 F)

Power

9V *1 Battery

Typical battery life
(Alkaline)

Non-laser mode: 22 hrs;
Laser Models:12 hrs

Weight

222g

Dimension

175x100x50mm

MADE IN CHINA

(Page 4)

(Page 5)

(Page 6)

Figure 2

2. Buttons: 

Figure 3

a) MAX: Measuring maximum temperature

b) MIN: Measuring minimum temperature

c) DIF: Basic on the reading before press 4key 

compute the difference of current reading

d) AVG: measuring average temperature

e) HAL: high temperature alarm, When selected HAL 

press 5 keys to set high temperature alarm trigger 
and confirmed by press 4 key. When reading over 
trigger, LCD display HI icon with BiBi audio sounds

f)

LAL: low temperature alarm, When select LAL. 
Press 5 keys to set low temperature trigger and 
confirmed by pressing 4 keys.  When reading over 
trigger. LCD display LOW icon with BiBi audio 
sounds.

g) STO: data storage. When selected STO, lock & 

DATA indicator will shown. when press 4 key. After 
temperature read out press 6 key to store then 
memory unit will shown. There 12 groups memory 
unit available. To recall the stored data in normal 
measuring mode by press 6 keys for 3 second.

h) EMS: Emissivity. Press 5 key for emissivity setting, 

press 4 keys to save setup and back to normal 
status

7) Celsius/Fahrenheit switch: Please open battery and 

push the slide switch for conversion